peb20560 Infineon Technologies Corporation, peb20560 Datasheet - Page 343

no-image

peb20560

Manufacturer Part Number
peb20560
Description
Dsp Oriented Pbx Controller Doc
Manufacturer
Infineon Technologies Corporation
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
peb20560HV3.1
Manufacturer:
INF
Quantity:
5 510
Part Number:
peb20560HV3.1
Manufacturer:
STK
Quantity:
5 510
Part Number:
peb20560V2.1
Manufacturer:
INFINEON
Quantity:
3 900
Part Number:
peb20560V2.1-33D0C
Manufacturer:
SIEMENS
Quantity:
5 510
Part Number:
peb20560V2.1-33D0C
Manufacturer:
MOT
Quantity:
5 510
Semiconductor Group
XDOV
XFW
Note: XFW is only valid when CEC = 0.
AREP/
XREP
RFR
RLI
Note: Significant in point-to-point configurations!
CEC
XAC
AFI
5.1.2.12
Access: read
Reset value: xx
RSTA always displays the momentary state of the receiver. Because this state can differ
from the last entry in the FIFO it is reasonable to always use the status bytes in the FIFO.
VFR
bit 7
VFR
Receive Status Register (RSTA)
Transmit Data Overflow.
A ‘1’ indicates, that more than 32 bytes have been written into the XFIFO.
XFIFO Write enable.
A ‘1’ indicates, that data can be written into the XFIFO.
Auto Repeat/Transmission Repeat.
Read back value of the corresponding command bit CMDR:AREP/XREP.
RFIFO Read enable.
A ‘1’ indicates, that valid data is in the RFIFO and read access is enabled.
RFR is set with the RME- or RPF-interrupt and reset when executing the
RMC-command.
Receiver Line Inactive.
Neither flags as inter frame time fill nor frames are received via the receive
line.
Command Execution.
When ‘0’ no command is currently executed, the CMDR-register can be
written to.
When ‘1’ a command (written previously to CMDR) is currently executed, no
further command must temporarily be written to the CMDR-register.
Transmitter Active.
A ‘1’ indicates, that the transmitter is currently active.
Additional Frame Indication.
A ‘1’ indicates, that one or more completely received frames or the last part
of a frame are in the CPU inaccessible part of the RFIFO.
In combination with the bit STAR:RFR multiple frames can be read out of the
RFIFO without interrupt control.
Valid Frame.
Indicates whether the received frame is valid (‘1’) or not (‘0’ invalid).
RDO
H
CRC
RAB
5-100
HA1
HA0
Description of Registers
C/R
PEB 20560
bit 0
2003-08
LA