am79c960 Advanced Micro Devices, am79c960 Datasheet - Page 25

no-image

am79c960

Manufacturer Part Number
am79c960
Description
Pcnettm-isa Single-chip Ethernet Controller
Manufacturer
Advanced Micro Devices
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
am79c960AKC
Manufacturer:
AMD
Quantity:
20 000
Part Number:
am79c960KC
Manufacturer:
AMD
Quantity:
5 510
Part Number:
am79c960KC
Manufacturer:
AMD
Quantity:
1 000
Part Number:
am79c960KC
Manufacturer:
AMD
Quantity:
1 000
Part Number:
am79c960KC
Manufacturer:
AMD
Quantity:
1 000
Part Number:
am79c960KC
Manufacturer:
AMD
Quantity:
1 000
Part Number:
am79c960KC
Manufacturer:
AMD
Quantity:
20 000
Part Number:
am79c960KC/W
Manufacturer:
AMD
Quantity:
2 792
instead.
PIN DESCRIPTION:
SHARED MEMORY MODE
ISA Interface
AEN
Address Enable
This signal must be driven LOW when the bus performs
an I/O access to the device.
IOCHRDY
I/O Channel Ready
When the PCnet-ISA controller is being accessed, a
HIGH on IOCHRDY indicates that valid data exists on
the data bus for reads and that data has been latched for
writes.
IOCS16
I/O Chip Select 16
When an I/O read or write operation is performed, the
PCnet-ISA controller will drive this pin LOW to indicate
that the chip supports a 16-bit operation at this address.
(If the motherboard does not receive this signal, then the
motherboard will convert a 16-bit access to two 8-bit ac-
cesses.) The IOCS16 pin is also an input and must go
HIGH at least once after reset for the PCnet-ISA control-
ler to perform 16-bit I/O operations. If this pin is
grounded then the PCnet-ISA controller only performs
8-bit I/O operations.
The PCnet-ISA controller follows the IEEE P996 specifi-
cation that recommends this function be implemented
as a pure decode of SA0-9 and AEN, with no depend-
ency on SMEMR, MEMR, MEMW, IOR, or IOW;
however, some PC/AT clone systems are not compat-
ible with this approach. For this reason, the PCnet-ISA
controller is recommended to be configured to run 8-bit
I/O on all machines. Since data is moved by memory cy-
cles there is virtually no performance loss incurred by
running 8-bit I/O and compatibility problems are virtually
eliminated. The PCnet-ISA controller can be configured
to run 8-bit-only I/O by disconnecting the IOCS16 pin
from the ISA bus and tying the IOCS16 pin to ground
IOR
I/O Read
To perform an Input/Output Read operation on the de-
vice IOR must be asserted. IOR is only valid if the AEN
signal is LOW and the external address matches the
PCnet-ISA controller ’s predefined I/O address location.
If valid, IOR indicates that a slave read operation is to be
performed.
IOW
I/O Write
To perform an Input/Output write operation on the de-
vice IOW must be asserted. IOW is only valid if AEN
signal is LOW and the external address matches the
PCnet-ISA controller’s predefined I/O address location.
If valid, IOW indicates that a slave write operation is to
be performed.
Input
Output
Input/Output
Input
Input
P R E L I M I N A R Y
Am79C960
IRQ
Interrupt Request
An attention signal which indicates that one or more of
the following status flags is set: BABL, MISS, MERR,
RINT, IDON or TXSTRT. All status flags have a mask bit
which allows for suppression of INTR assertion. These
flags have the following meaning:
MEMR
Memory Read
MEMR goes LOW to perform a memory read operation.
MEMW
Memory Write
MEMW goes LOW to perform a memory write
operation.
RESET
Reset
When RESET is asserted HIGH, the PCnet-ISA control-
ler performs an internal system reset. RESET must be
held for a minimum of 10 XTAL1 periods before being
deasserted. While in a reset state, the PCnet-ISA con-
troller will tristate or deassert all outputs to predefined
reset levels. The PCnet-ISA controller resets itself upon
power-up.
SA0-9
System Address Bus
This bus carries the address inputs from the system ad-
dress bus. Address data is stable during command
active cycle.
SBHE
System Bus High Enable
This signal indicates the HIGH byte of the system data
bus is to be used. There is a weak pull-up resistor on this
pin. If the PCnet-ISA controller is installed in an 8-bit
only system like the PC/XT, SBHE will always be HIGH
and the PCnet-ISA controller will perform only 8-bit op-
erations. There must be at least one LOW going edge on
this signal before the PCnet-ISA controller will perform
16-bit operations.
BABL
RCVCCO
JAB
MISS
MERR
MFCO
RINT
IDON
TXSTRT
Babble
Receive Collision Count Overflow
Jabber
Missed Frame
Memory Error
Missed Frame Count Overflow
Receive Interrupt
Initialization Done
Transmit Start
Output
Input
Input
Input
Input
Input
AMD
1-367