S9S12G64F0MLF Freescale Semiconductor, S9S12G64F0MLF Datasheet - Page 811

no-image

S9S12G64F0MLF

Manufacturer Part Number
S9S12G64F0MLF
Description
16-bit Microcontrollers - MCU S12 Core,64kFlash,Au
Manufacturer
Freescale Semiconductor
Datasheet

Specifications of S9S12G64F0MLF

Rohs
yes
Core
S12
Processor Series
MC9S12G
Data Bus Width
16 bit
Maximum Clock Frequency
25 MHz
Program Memory Size
64 KB
Data Ram Size
2 KB
On-chip Adc
Yes
Operating Supply Voltage
3.13 V to 5.5 V
Operating Temperature Range
- 40 C to + 125 C
Package / Case
LQFP-48
Mounting Style
SMD/SMT

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
S9S12G64F0MLF
Manufacturer:
IR
Quantity:
4 200
Part Number:
S9S12G64F0MLF
Manufacturer:
FREESCALE
Quantity:
2 500
Part Number:
S9S12G64F0MLF
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
Part Number:
S9S12G64F0MLF
Manufacturer:
FREESCALE
Quantity:
2 500
Part Number:
S9S12G64F0MLF
Manufacturer:
FREESCALE
Quantity:
20 000
Company:
Part Number:
S9S12G64F0MLF
Quantity:
1 961
Part Number:
S9S12G64F0MLFR
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
24.4.6.6
The Program Once command restricts programming to a reserved 64 byte field (8 phrases) in the
nonvolatile information register located in P-Flash. The Program Once reserved field can be read using the
Read Once command as described in
once since the nonvolatile information register in P-Flash cannot be erased. The Program Once command
must not be executed from the Flash block containing the Program Once reserved field to avoid code
runaway.
Upon clearing CCIF to launch the Program Once command, the Memory Controller first verifies that the
selected phrase is erased. If erased, then the selected phrase will be programmed and then verified with
read back. The CCIF flag will remain clear, setting only after the Program Once operation has completed.
The reserved nonvolatile information register accessed by the Program Once command cannot be erased
and any attempt to program one of these phrases a second time will not be allowed. Valid phrase index
values for the Program Once command range from 0x0000 to 0x0007. During execution of the Program
Once command, any attempt to read addresses within P-Flash will return invalid data.
Freescale Semiconductor
1
As defined by the memory map for FTMRG32K1.
Register
FSTAT
Program Once Command
CCOBIX[2:0]
MGSTAT1
MGSTAT0
ACCERR
Error Bit
Table 24-40. Program Once Command FCCOB Requirements
FPVIOL
000
001
010
011
100
101
Table 24-39. Program P-Flash Command Error Handling
MC9S12G Family Reference Manual, Rev.1.23
Set if CCOBIX[2:0] != 101 at command launch
Set if command not available in current mode (see
Set if an invalid global address [17:0] is supplied see
Set if a misaligned phrase address is supplied (global address [2:0] != 000)
Set if the global address [17:0] points to a protected area
Set if any errors have been encountered during the verify operation
Set if any non-correctable errors have been encountered during the verify
operation
Section
Program Once phrase index (0x0000 - 0x0007)
0x07
24.4.6.4. The Program Once command must only be issued
Program Once word 0 value
Program Once word 1 value
Program Once word 2 value
Program Once word 3 value
FCCOB Parameters
Error Condition
Not Required
16 KByte Flash Module (S12FTMRG16K1V1)
Table
Table
24-25)
24-3)
1
813

Related parts for S9S12G64F0MLF