MC9S08DV32ACLF Freescale Semiconductor, MC9S08DV32ACLF Datasheet - Page 269

IC MCU 32K FLASH 2K RAM 48-LQFP

MC9S08DV32ACLF

Manufacturer Part Number
MC9S08DV32ACLF
Description
IC MCU 32K FLASH 2K RAM 48-LQFP
Manufacturer
Freescale Semiconductor
Series
HCS08r
Datasheets

Specifications of MC9S08DV32ACLF

Core Processor
HCS08
Core Size
8-Bit
Speed
40MHz
Connectivity
CAN, I²C, LIN, SCI, SPI
Peripherals
LVD, POR, PWM, WDT
Number Of I /o
39
Program Memory Size
32KB (32K x 8)
Program Memory Type
FLASH
Ram Size
2K x 8
Voltage - Supply (vcc/vdd)
2.7 V ~ 5.5 V
Data Converters
A/D 16x12b
Oscillator Type
External
Operating Temperature
-40°C ~ 85°C
Package / Case
48-LQFP
Processor Series
S08DV
Core
HCS08
Data Bus Width
8 bit
Data Ram Size
2 KB
Interface Type
CAN, I2C, SCI, SPI
Number Of Programmable I/os
26
Operating Supply Voltage
5.5 V
Mounting Style
SMD/SMT
3rd Party Development Tools
EWS08
Development Tools By Supplier
DEMO9S08DZ60
On-chip Adc
12 bit, 10 channel
Controller Family/series
HCS08
No. Of I/o's
39
Ram Memory Size
2KB
Cpu Speed
40MHz
No. Of Timers
2
Digital Ic Case Style
LQFP
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MC9S08DV32ACLF
Manufacturer:
FREESCALE
Quantity:
2 000
Part Number:
MC9S08DV32ACLF
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
Part Number:
MC9S08DV32ACLF
Manufacturer:
FREESCALE
Quantity:
2 000
12.6.2
The bus-off recovery is user configurable. The bus-off state can either be exited automatically or on user
request.
For reasons of backwards compatibility, the MSCAN defaults to automatic recovery after reset. In this
case, the MSCAN will become error active again after counting 128 occurrences of 11 consecutive
recessive bits on the CAN bus (See the Bosch CAN specification for details).
If the MSCAN is configured for user request (BORM set in
(CANCTL1)”), the recovery from bus-off starts after both independent events have become true:
These two events may occur in any order.
Freescale Semiconductor
128 occurrences of 11 consecutive recessive bits on the CAN bus have been monitored
BOHOLD in
the user
Bus-Off Recovery
Section 12.3.12, “MSCAN Miscellaneous Register (CANMISC)
MC9S08DV60 Series Data Sheet, Rev 3
Chapter 12 Freescale’s Controller Area Network (S08MSCANV1)
Section 12.3.2, “MSCAN Control Register 1
has been cleared by
269

Related parts for MC9S08DV32ACLF