HD6417727BP100BV Renesas Electronics America, HD6417727BP100BV Datasheet - Page 526

IC SUPERH MPU ROMLESS 240BGA

HD6417727BP100BV

Manufacturer Part Number
HD6417727BP100BV
Description
IC SUPERH MPU ROMLESS 240BGA
Manufacturer
Renesas Electronics America
Series
SuperH® SH7700r
Datasheet

Specifications of HD6417727BP100BV

Core Processor
SH-3 DSP
Core Size
32-Bit
Speed
100MHz
Connectivity
FIFO, SCI, SIO, SmartCard, USB
Peripherals
DMA, LCD, POR, WDT
Number Of I /o
104
Program Memory Type
ROMless
Ram Size
32K x 8
Voltage - Supply (vcc/vdd)
1.6 V ~ 2.05 V
Data Converters
A/D 6x10b; D/A 2x8b
Oscillator Type
Internal
Operating Temperature
-20°C ~ 75°C
Package / Case
240-BGA
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Eeprom Size
-
Program Memory Size
-
Section 16 Realtime Clock (RTC)
RMINAR, RHRAR, RWKAR, RDAYAR, and RMONAR registers are checked, and when the
ENB bit is set to 1, the alarm register and the corresponding counter are compared. If all values in
the specified alarm registers and the corresponding counters match, an RTC alarm interrupt is
generated.
The settable range is “01 to 31 in decimal + ENB bit”. If other values are set, correct operation is
not provided. The settable RDAYCNT range differs according to the month and leap year. Please
confirm the correct setting.
Only the ENB bit in RDAYAR is initialized to 0 by a power-on reset, and the other bits are not
initialized. The RDAYAR contents are retained after a manual reset or in standby mode.
16.2.14 Month Alarm Register (RMONAR)
The month alarm register (RMONAR) is an 8-bit read/write alarm register that corresponds to the
BCD-coded month section counter RMONCNT of the RTC. When the ENB bit is set to 1in
RMONAR, the RMONAR value and RMONCNT value are compared. In this way, the RSECAR,
RMINAR, RHRAR, RWKAR, RDAYAR, and RMONAR registers are checked, and when the
ENB bit is set to 1, the alarm register and the corresponding counter are compared. If all values in
the specified alarm registers and the corresponding counters match, an RTC alarm interrupt is
generated.
The settable range is “01 to 12 in decimal + ENB bit”. If other values are set, correct operation is
not provided.
Only the ENB bit in RMONAR is initialized to 0 by a power-on reset, and the other bits are not
initialized. The RMONAR contents are retained after a manual reset or in standby mode.
Rev.6.00 Mar. 27, 2009 Page 468 of 1036
REJ09B0254-0600
Initial value:
Initial value:
R/W:
R/W:
Bit:
Bit:
ENB
ENB
R/W
R/W
7
0
7
0
R
R
6
0
6
0
R/W
R
5
5
0
10 days
months
R/W
R/W
10
4
4
R/W
R/W
3
3
R/W
R/W
2
2
1 month
1 day
R/W
R/W
1
1
R/W
R/W
0
0

Related parts for HD6417727BP100BV