EP1S20F484C6N Altera, EP1S20F484C6N Datasheet - Page 782

IC STRATIX FPGA 20K LE 484-FBGA

EP1S20F484C6N

Manufacturer Part Number
EP1S20F484C6N
Description
IC STRATIX FPGA 20K LE 484-FBGA
Manufacturer
Altera
Series
Stratix®r
Datasheet

Specifications of EP1S20F484C6N

Number Of Logic Elements/cells
18460
Number Of Labs/clbs
1846
Total Ram Bits
1669248
Number Of I /o
361
Voltage - Supply
1.425 V ~ 1.575 V
Mounting Type
Surface Mount
Operating Temperature
0°C ~ 85°C
Package / Case
484-FBGA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Number Of Gates
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EP1S20F484C6N
Manufacturer:
ALTERA
Quantity:
534
Part Number:
EP1S20F484C6N
Manufacturer:
Altera
Quantity:
10 000
Part Number:
EP1S20F484C6N
Manufacturer:
ALTERA
0
Remote Configuration Operation
12–4
Stratix Device Handbook, Volume 2
page address of the application configuration that should be loaded into
the Stratix or Stratix GX device. If an error occurs during user mode of an
application configuration, the device reloads the default factory
configuration page.
mode.
Figure 12–3. Remote Configuration Mode
Local Configuration Mode
Local configuration mode—a simplified version of remote configuration
mode—is suitable for systems that load an application immediately upon
power-up. In this mode you can only use one application configuration,
which you can update either remotely or locally.
In local configuration mode, upon power-up, or when nCONFIG is
asserted, the Stratix or Stratix GX device loads the application
configuration immediately. Factory configuration loads only if an error
occurs during the application configuration’s user mode. If you use an
enhanced configuration device, page address 001 is the location for the
application configuration data, and page address 000 is the location for
the factory configuration data.
If the configuration data at page address 001 does not load correctly due
to cyclic redundancy code (CRC) failure, or it times-out of the enhanced
configuration device, or the external processor times-out, then the factory
configuration located at the default page (page address 000) loads into
the Stratix or Stratix GX device.
In local configuration mode (shown in
timer is disabled. For more information on the watchdog timer, see
“Watchdog Timer” on page
Configuration
Error
Figure 12–3
Power Up
Configuration
Page (000)
12–7.
Factory
Errors
shows a diagram of remote configuration
Application 7
Configuration
Reconfigure
PGM [111]
Figure
Errors
Reconfigure
12–4), the user watchdog
Configuration
Application 1
PGM [001]
Altera Corporation
September 2004

Related parts for EP1S20F484C6N