PEB2255H-V13 Infineon Technologies, PEB2255H-V13 Datasheet - Page 64

IC INTERFACE LINE 80-MQFP

PEB2255H-V13

Manufacturer Part Number
PEB2255H-V13
Description
IC INTERFACE LINE 80-MQFP
Manufacturer
Infineon Technologies
Datasheet

Specifications of PEB2255H-V13

Applications
*
Interface
*
Voltage - Supply
*
Package / Case
80-SQFP
Mounting Type
Surface Mount
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
PEB2255H-V13
PEB2255H-V13IN

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PEB2255H-V13
Manufacturer:
Infineon Technologies
Quantity:
10 000
is given out via port RDO. If the receive buffer is bypassed, data is clocked off with RCLK
instead of SCLKR.
In one frame or short buffer mode the delay through the receive buffer is reduced to an
average delay of 128 or 46 bits. Slips are performed in all buffer modes except the
bypass mode. After a slip is detected the read pointer is adjusted to one half of the
current buffer size.
The following table gives an overview of the receive buffer operating mode.
Note: Combinations of SIC1.RBS1...0 and LOOP.SFM other than described are not
•.
Table 12
SIC1.RBS1...0
11
LOOP.SFM = 0
10
LOOP.SFM = 0
01
LOOP.SFM = 0
00
LOOP.SFM = 1
00
LOOP.SFM = 0
1)
Data Sheet
In bypass mode the clock provided on pin SCLKR is ignored. Clocking is done with RCLK.
allowed. The use of LOOP.SFM = 1 is not recommended, but possible for
FALC
®
54 compatibility.
Receive Buffer Operating Modes (E1)
Buffer Size
bypass
short buffer
1 frame
1 frame
2 frames
1)
TS Offset programing
(RC1...0)
RFM (SYPR = output) must
be selected; value of
RC1...0 determines the
position of RFM
RFM (SYPR = output) must
be selected; value of
RC1...0 determines the
position of RFM
RFM (SYPR = output) must
be selected; value of
RC1...0 determines the
position of RFM
SYPR is input and
determines the frame
position together with
RC1...0 offset.
SYPR is input and
determines the frame
position together with
RC1...0 offset.
64
Functional Description E1
Slip performance
no slips
yes
yes
Slip conditions are
detected and reported,
but no slip is performed.
Slips have to be initiated
by software
(reprogramming of
RC1...0).
yes
Slips are performed on
the frame boundary
FALC-LH V1.3
PEB 2255
2000-07