PEB2075 INFINEON [Infineon Technologies AG], PEB2075 Datasheet - Page 118

no-image

PEB2075

Manufacturer Part Number
PEB2075
Description
ICs for Communications Extended PCM Interface Controller
Manufacturer
INFINEON [Infineon Technologies AG]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PEB2075N
Quantity:
6 250
Part Number:
PEB2075N
Quantity:
6 250
Part Number:
PEB2075N
Manufacturer:
SIEMENS
Quantity:
5 510
Part Number:
PEB2075N
Manufacturer:
INTERSIL
Quantity:
5 510
Part Number:
PEB2075N
Manufacturer:
SIEMEMS
Quantity:
20 000
Part Number:
PEB2075N V1��3
Manufacturer:
SIEMENS
Quantity:
3
Part Number:
PEB2075N-V1.3
Manufacturer:
SIEMENS/西门子
Quantity:
20 000
Part Number:
PEB2075N-V13TR
Manufacturer:
LT
Quantity:
512
Part Number:
PEB2075N-V13TR
Manufacturer:
Infineon Technologies
Quantity:
10 000
Part Number:
PEB2075NV1.3
Manufacturer:
PHILIPS/飞利浦
Quantity:
20 000
Part Number:
PEB2075P
Manufacturer:
SIEMENS/西门子
Quantity:
20 000
CFI Bit Timing and Bit Shift CMD2, CTAR, CBSR
The position of the CFI frame can be shifted relative to the CFI frame synchronization
pulse using the CFI Time slot Adjustment Register CTAR and the CFI Bit Shift Register
CBSR. This shifting can be performed simultaneously for up- and downstream directions
with a one bit resolution by up to a whole frame. The upstream frame can additionally be
shifted relative to the downstream frame by up to 15 bits. Furthermore, the polarity of the
clock edge (CRCL) used for transmitting and sampling the data can be programmed in
the CMD2 register.
Since the frame synchronization source of the configurable interface is either PFS (for
CMD1:CSS = 0) or FSC (for CMD1:CSS = 1), the bit shift also refers to either the PFS
or the FSC framing signal.
Note: If PFS/PDC is selected as CFI sync/clock source, the time slot and bit shift
If FSC/DCL is selected as CFI sync/clock source, the time slot and bit shift functions
affect the CFI frame with respect to the FSC framing input signal. In this case, the CFI
frame start can be selected completely independently from the PCM frame start, it must
only be assured that a phase relationship once established between the CFI and PCM
frames is maintained all the time.
Semiconductor Group
values programmed to CTAR and CBSR:CDS2 … 0 affect both the CFI data lines
and the CFI output framing signal FSC. The CFI frame together with the FSC
signal can thus be shifted with respect to the PCM frame (PFS). The position of
the CFI frame relative to the FSC output signal is not affected by these settings
but is instead determined by the FSC framing control mode programmed to
CMD2:FC2 … 0. The upstream CFI frame can, however, still be shifted relative to
the downstream CFI frame with the CBSR:CUS3 … 0 bits.