PEB2075 INFINEON [Infineon Technologies AG], PEB2075 Datasheet - Page 142

no-image

PEB2075

Manufacturer Part Number
PEB2075
Description
ICs for Communications Extended PCM Interface Controller
Manufacturer
INFINEON [Infineon Technologies AG]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PEB2075N
Quantity:
6 250
Part Number:
PEB2075N
Quantity:
6 250
Part Number:
PEB2075N
Manufacturer:
SIEMENS
Quantity:
5 510
Part Number:
PEB2075N
Manufacturer:
INTERSIL
Quantity:
5 510
Part Number:
PEB2075N
Manufacturer:
SIEMEMS
Quantity:
20 000
Part Number:
PEB2075N V1��3
Manufacturer:
SIEMENS
Quantity:
3
Part Number:
PEB2075N-V1.3
Manufacturer:
SIEMENS/西门子
Quantity:
20 000
Part Number:
PEB2075N-V13TR
Manufacturer:
LT
Quantity:
512
Part Number:
PEB2075N-V13TR
Manufacturer:
Infineon Technologies
Quantity:
10 000
Part Number:
PEB2075NV1.3
Manufacturer:
PHILIPS/飞利浦
Quantity:
20 000
Part Number:
PEB2075P
Manufacturer:
SIEMENS/西门子
Quantity:
20 000
W:MACR
wait for STAR:MAC = 0
R:MADR
5.3.3.3 Access to the Control Memory Data Field
Writing to or reading the control memory (CM) data field may serve different purposes
depending on the function given to the corresponding CFI time slot which is defined by
the 4 bit code field value:
There are two types of commands which give access to the CM data field:
The memory operation code MACR:MOC = 111X is used for writing to the CM data field
and code field simultaneously. The MADR content is transferred to the data field while
the MACR:CMC3 … 0 bits are transferred to the code field. This command is explained
in more detail in chapter 5.3.3.4.
The memory operation code MACR:MOC = 1001 is used for reading or writing to the CM
data field. Since the CM code field is not affected, this command makes only sense if the
related CFI time slot has already the desired functionality.
The Procedure for Writing to the CM Data Field (using the MOC = 1001 command)
is
W:MADR
W:MADR
R:MADR
For test purposes this setting shall be read back:
W:MAAR
Table 23
CFI Time Slot Application
Switched channel
Preprocessed channel
The Procedure for Reading the CM Data Field is
W:MAAR
W:MACR
wait for STAR:MAC = 0
R:MADR
Semiconductor Group
P channel
= 1010 1010
= 1110 0000
= XXXX 1001
= value
= CFI time slot address according figure 48
= 0100 1000
= CFI time slot address according figure 48
= 1100 1000
= value
B
B
B
B
B
= E0
= 48
= C8
; address of upstream PCM port 1, time slot 10
; read back of MD3 … 0
according to figure 48
H
H
H
; read access with MOC = 1100
142
Meaning of CM Data Field
Pointer to PCM interface
C/I or SIG value
CFI idle code
Application Hints
PEB 2055
PEF 2055

Related parts for PEB2075