PEB2075 INFINEON [Infineon Technologies AG], PEB2075 Datasheet - Page 166

no-image

PEB2075

Manufacturer Part Number
PEB2075
Description
ICs for Communications Extended PCM Interface Controller
Manufacturer
INFINEON [Infineon Technologies AG]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PEB2075N
Quantity:
6 250
Part Number:
PEB2075N
Quantity:
6 250
Part Number:
PEB2075N
Manufacturer:
SIEMENS
Quantity:
5 510
Part Number:
PEB2075N
Manufacturer:
INTERSIL
Quantity:
5 510
Part Number:
PEB2075N
Manufacturer:
SIEMEMS
Quantity:
20 000
Part Number:
PEB2075N V1��3
Manufacturer:
SIEMENS
Quantity:
3
Part Number:
PEB2075N-V1.3
Manufacturer:
SIEMENS/西门子
Quantity:
20 000
Part Number:
PEB2075N-V13TR
Manufacturer:
LT
Quantity:
512
Part Number:
PEB2075N-V13TR
Manufacturer:
Infineon Technologies
Quantity:
10 000
Part Number:
PEB2075NV1.3
Manufacturer:
PHILIPS/飞利浦
Quantity:
20 000
Part Number:
PEB2075P
Manufacturer:
SIEMENS/西门子
Quantity:
20 000
output time slot is later in time than the input time slot, the data received in frame N will
only be transmitted in frame N + 1 or even N + 2 (see figure 60 b)) and figure 60 c)).
Figure 60
Switching Delays
5.4.4
When a channel is switched from an input time slot (e.g. from the PCM interface) to an
output time slot (e.g. to the CFI), it is sometimes useful to know the frame delay
introduced by this connection. This is of prime importance for example if channels having
a bandwidth of n
the EPIC. If all 6 time slots of an H0 channel are not submitted to the same frame delay,
time slot integrity is no longer maintained.
Since the EPIC has only a one frame buffer, the switching delay depends mainly on the
location of the output time slot with respect to the input time slot. If there is “enough” time
between the two locations, the EPIC switches the input data to the output data within the
same frame (see figure 60 a)). If the time between the two locations is too small or if the
Semiconductor Group
a) Switching Delay : 0 Frames
Input Frame
Output Frame
b) Switching Delay : 1 Frames
Input Frame
Output Frame
c) Switching Delay : 2 Frames
Input Frame
Output Frame
Switching Delays
64 kbit/s (e.g. H0 channels: 6
N
N
N
N
N
N
166
N + 1
N + 1
N + 1
N + 1
N + 1
N + 1
64 = 384 kbit/s) shall be switched by
N + 2
N + 2
N + 2
N + 2
N + 2
N + 2
+
Application Hints
ITD08075
PEB 2055
PEF 2055