PEB2075 INFINEON [Infineon Technologies AG], PEB2075 Datasheet - Page 58

no-image

PEB2075

Manufacturer Part Number
PEB2075
Description
ICs for Communications Extended PCM Interface Controller
Manufacturer
INFINEON [Infineon Technologies AG]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PEB2075N
Quantity:
6 250
Part Number:
PEB2075N
Quantity:
6 250
Part Number:
PEB2075N
Manufacturer:
SIEMENS
Quantity:
5 510
Part Number:
PEB2075N
Manufacturer:
INTERSIL
Quantity:
5 510
Part Number:
PEB2075N
Manufacturer:
SIEMEMS
Quantity:
20 000
Part Number:
PEB2075N V1��3
Manufacturer:
SIEMENS
Quantity:
3
Part Number:
PEB2075N-V1.3
Manufacturer:
SIEMENS/西门子
Quantity:
20 000
Part Number:
PEB2075N-V13TR
Manufacturer:
LT
Quantity:
512
Part Number:
PEB2075N-V13TR
Manufacturer:
Infineon Technologies
Quantity:
10 000
Part Number:
PEB2075NV1.3
Manufacturer:
PHILIPS/飞利浦
Quantity:
20 000
Part Number:
PEB2075P
Manufacturer:
SIEMENS/西门子
Quantity:
20 000
Semiconductor Group
4.2.2.3 Configurable Interface Bit Number Register (CBNR)
Access in demultiplexed P-interface mode:
Access in multiplexed P-interface mode:
Reset value: FF
CBN7..0
4.2.2.4 Configurable Interface Time Slot Adjustment Register (CTAR)
Access in demultiplexed P-interface mode:
Access in multiplexed P-interface mode:
Reset value: 00
TSN6..0
Note: If CMD1:CSS = 0, the CFI frame will be shifted - together with the FSC output
bit 7
bit 7
CBN7
0
signal - with respect to PFS. The position of the CFI frame relative to the FSC
output signal is not affected by these settings, but is instead determined by
CMD2:FC2..0.
If CMD1:CSS = 1, the CFI frame will be shifted with respect to the FSC-input
signal.
CFI Bit Number 7..0.
The number of bits that constitute a CFI frame must be programmed to
CMD2, CBNR:CBN9..0 as indicated below.
CBN9..0 = number of bits
For a 8-kHz frame structure, the number of bits per frame can be derived
from the data rate by division with 8000.
Time Slot Number.
The CFI framing signal (PFS if CMD1:CSS = 0 or FSC if CMD1:CSS = 1)
marks the CFI time slot called TSN according to the following formula:
TSN6..0 = TSN + 2
E.g.: If the framing signal is to mark time slot 0 (bit 7), CTAR must be set to
02
CBN6
TSN6
H
H
(CBSR to 20
H
CBN5
TSN5
H
).
CBN4
TSN4
1
58
CBN3
TSN3
read/write
read/write
read/write
read/write
Detailed Register Description
CBN2
TSN2
OMDR:RBS = 1
address: 30
address: 9
OMDR:RBS = 1
address: 32
address: 8
CBN1
TSN1
PEB 2055
PEF 2055
H
H
bit 0
bit 0
H
H
CBN0
TSN0

Related parts for PEB2075