PEB2075 INFINEON [Infineon Technologies AG], PEB2075 Datasheet - Page 152

no-image

PEB2075

Manufacturer Part Number
PEB2075
Description
ICs for Communications Extended PCM Interface Controller
Manufacturer
INFINEON [Infineon Technologies AG]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PEB2075N
Quantity:
6 250
Part Number:
PEB2075N
Quantity:
6 250
Part Number:
PEB2075N
Manufacturer:
SIEMENS
Quantity:
5 510
Part Number:
PEB2075N
Manufacturer:
INTERSIL
Quantity:
5 510
Part Number:
PEB2075N
Manufacturer:
SIEMEMS
Quantity:
20 000
Part Number:
PEB2075N V1��3
Manufacturer:
SIEMENS
Quantity:
3
Part Number:
PEB2075N-V1.3
Manufacturer:
SIEMENS/西门子
Quantity:
20 000
Part Number:
PEB2075N-V13TR
Manufacturer:
LT
Quantity:
512
Part Number:
PEB2075N-V13TR
Manufacturer:
Infineon Technologies
Quantity:
10 000
Part Number:
PEB2075NV1.3
Manufacturer:
PHILIPS/飞利浦
Quantity:
20 000
Part Number:
PEB2075P
Manufacturer:
SIEMENS/西门子
Quantity:
20 000
8 bit time slot:
32 kbit/s channel
32 kbit/s channel
16 kbit/s channel
16 kbit/s channel
16 kbit/s channel
16 kbit/s channel
5.4.1
All time slot assignments are programmed in the control memory (CM). Each line
(address) of the CM refers to one CFI time slot. The MAAR register, which is used to
address the CM, therefore specifies the CFI port and time slot to be switched. The data
field of the CM contains a pointer which points to a location in the data memory (DM).
The data memory contains the actual PCM data to be switched. The MADR register
contains the data to be copied to the CM data field. Since this data is interpreted as a
pointer to the DM, the MADR contents therefore specifies the PCM port and time slot to
be switched. The 4 bit CM code field must finally contain a value to declare the
corresponding CFI time slot as a switched channel (codes with a leading 0). This code
must be written at least once to the CM using the MACR register.
Since the CFI - PCM time slot assignment is programmed at the CFI side, it is possible
to switch a single downstream PCM time slot to several downstream CFI time slots. It is,
however, not possible to switch a single upstream CFI time slot to several upstream
PCM time slots.
If several upstream 64 kbit/s CFI time slots are assigned to the same upstream 64 kbit/s
PCM time slot, only the data of one CFI time slot will actually be switched since each
upstream connection will simply overwrite the DM data field. This switching mode can
therefore only effectively be used if the upstream switching is performed on different
subtime slot locations within the same PCM time slot (refer to chapter 5.4.2).
The following sequences can be used to program, verify, and cancel a CFI - PCM time
slot connection:
Semiconductor Group
CFI - PCM Time Slot Assignment
7
7
7
6
6
6
5
5
5
152
4
4
4
3
3
3
2
2
2
Application Hints
1
1
1
PEB 2055
PEF 2055
0
0
0