LPC47N237-MD SMSC [SMSC Corporation], LPC47N237-MD Datasheet - Page 39

no-image

LPC47N237-MD

Manufacturer Part Number
LPC47N237-MD
Description
3.3V I/O CONTROLLER FOR PORT REPLICATORS AND DOCKING STATIONS
Manufacturer
SMSC [SMSC Corporation]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LPC47N237-MD
Manufacturer:
SMSC
Quantity:
45
Part Number:
LPC47N237-MD
Manufacturer:
FUJI
Quantity:
575
Part Number:
LPC47N237-MD
Manufacturer:
SMSC
Quantity:
1 000
3.3v I/O Controller for Port Replicators and Docking Stations
8.5
SMSC DS – LPC47N237
BAUD RATE
2.
3.
4.
When the XMIT FIFO and transmitter interrupts are enabled (FCR bit 0 = "1", IER bit 1 = "1"), XMIT
interrupts occur as follows:
1.
2.
Character timeout and RCVR FIFO trigger level interrupts have the same priority as the current received
data available interrupt; XMIT FIFO empty has the same priority as the current transmitter holding register
empty interrupt.
FIFO Polled Mode Opertion
With FCR bit 0 = "1" resetting IER bits 0, 1, 2 or 3 or all to zero puts the UART in the FIFO Polled Mode of
operation. Since the RCVR and XMITTER are controlled separately, either one or both can be in the
polled mode of operation. In this mode, the user's program will check RCVR and XMITTER status via the
LSR. LSR definitions for the FIFO Polled Mode are as follows:
There is no trigger level reached or timeout condition indicated in the FIFO Polled Mode, however, the
RCVR and XMIT FIFOs are still fully capable of holding characters.
DESIRED
134.5
110
150
300
600
50
75
This will cause a maximum character received to interrupt issued delay of 160 msec at 300 BAUD with
a 12 bit character.
Character times are calculated by using the RCLK input for a clock signal (this makes the delay
proportional to the baudrate).
When a timeout interrupt has occurred it is cleared and the timer reset when the CPU reads one
character from the RCVR FIFO.
When a timeout interrupt has not occurred the timeout timer is reset after a new character is received
or after the CPU reads the RCVR FIFO.
The transmitter holding register interrupt (02H) occurs when the XMIT FIFO is empty; it is cleared as
soon as the transmitter holding register is written to (1 of 16 characters may be written to the XMIT
FIFO while servicing this interrupt) or the IIR is read.
The transmitter FIFO empty indications will be delayed 1 character time minus the last stop bit time
whenever the following occurs: THRE=1 and there have not been at least two bytes at the same time
in the transmitter FIFO since the last THRE=1. The transmitter interrupt after changing FCR0 will be
immediate, if it is enabled.
Bit 0=1 as long as there is one byte in the RCVR FIFO.
Bits 1 to 4 specify which error(s) have occurred. Character error status is handled the same way as
when in the interrupt mode, the IIR is not affected since EIR bit 2=0.
Bit 5 indicates when the XMIT FIFO is empty.
Bit 6 indicates that both the XMIT FIFO and shift register are empty.
Bit 7 indicates whether there are any errors in the RCVR FIFO.
GENERATE 16X CLOCK
DIVISOR USED TO
2304
1536
1047
857
768
384
192
Table 8.3 – UART Baud Rates
DATASHEET
Page 39
BETWEEN DESIRED AND ACTUAL
PERCENT ERROR DIFFERENCE
(NOTE 8.2
0.001
0.004
-
-
-
-
-
)
SPEED BIT
(NOTE 8.3
Revision 0.3 (10-26-04)
HIGH
X
X
X
X
X
X
X
)

Related parts for LPC47N237-MD