LPC47N237-MD SMSC [SMSC Corporation], LPC47N237-MD Datasheet - Page 69

no-image

LPC47N237-MD

Manufacturer Part Number
LPC47N237-MD
Description
3.3V I/O CONTROLLER FOR PORT REPLICATORS AND DOCKING STATIONS
Manufacturer
SMSC [SMSC Corporation]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LPC47N237-MD
Manufacturer:
SMSC
Quantity:
45
Part Number:
LPC47N237-MD
Manufacturer:
FUJI
Quantity:
575
Part Number:
LPC47N237-MD
Manufacturer:
SMSC
Quantity:
1 000
3.3v I/O Controller for Port Replicators and Docking Stations
11.1.1 SER_IRQ Cycle Control
11.1.2 SER_IRQ Data Frame
SMSC DS – LPC47N237
There are two modes of operation for the SER_IRQ Start Frame.
1.
2.
Once a Start Frame has been initiated, the LPC47N237 will watch for the rising edge of the Start Pulse and
start counting IRQ/Data Frames from there.
Recovery phase, and Turn-around phase. During the Sample phase the LPC47N237 drives the SER_IRQ
low, if and only if, its last detected IRQ/Data value was low. If its detected IRQ/Data value is high,
SER_IRQ is left tri-stated. During the Recovery phase the LPC47N237 drives the SER_IRQ high, if and
only if, it had driven the SER_IRQ low during the previous Sample Phase. During the Turn-around Phase
the LPC47N237 tri-states the SER_IRQ. The LPC47N237 will drive the SER_IRQ line low at the
appropriate sample point if its associated IRQ/Data line is low, regardless of which device initiated the Start
Frame.
The Sample Phase for each IRQ/Data follows the low to high transition of the Start Frame pulse by a
number of clocks equal to the IRQ/Data Frame times three, minus one. (e.g. The IRQ5 Sample clock is
the sixth IRQ/Data Frame, (6 x 3) - 1 = 17th clock after the rising edge of the Start Pulse).
SER_IRQ PERIOD
Quiet (Active) Mode: Any device may initiate a Start Frame by driving the SER_IRQ low for one
clock, while the SER_IRQ is Idle. After driving low for one clock the SER_IRQ is immediately tri-
stated without at any time driving high. A Start Frame may not be initiated while the SER_IRQ is
Active. The SER_IRQ is Idle between Stop and Start Frames. The SER_IRQ is Active between Start
and Stop Frames. This mode of operation allows the SER_IRQ to be Idle when there are no IRQ/Data
transitions which should be most of the time.
Once a Start Frame has been initiated the Host Controller will take over driving the SER_IRQ low in
the next clock and will continue driving the SER_IRQ low for a programmable period of three to seven
clocks. This makes a total low pulse width of four to eight clocks. Finally, the Host Controller will drive
the SER_IRQ back high for one clock, then tri-state.
Any SER_IRQ Device (i.e., The LPC47N237) which detects any transition on an IRQ/Data line for
which it is responsible must initiate a Start Frame in order to update the Host Controller unless the
SER_IRQ is already in an SER_IRQ Cycle and the IRQ/Data transition can be delivered in that
SER_IRQ Cycle.
Continuous (Idle) Mode: Only the Host controller can initiate a Start Frame to update IRQ/Data line
information. All other SER_IRQ agents become passive and may not initiate a Start Frame. SER_IRQ
will be driven low for four to eight clocks by Host Controller. This mode has two functions. It can be
used to stop or idle the SER_IRQ or the Host Controller can operate SER_IRQ in a continuous mode
by initiating a Start Frame at the end of every Stop Frame.
An SER_IRQ mode transition can only occur during the Stop Frame. Upon reset, SER_IRQ bus is
defaulted to Continuous mode, therefore only the Host controller can initiate the first Start Frame.
Slaves must continuously sample the Stop Frames pulse width to determine the next SER_IRQ
Cycle’s mode.
1
2
3
4
5
Table 11.1 - SER_IRQ Sampling Periods
DATASHEET
SIGNAL SAMPLED
Not Used
IRQ1
IRQ2
IRQ3
IRQ4
Page 69
Each IRQ/Data Frame is three clocks: Sample phase,
# OF CLOCKS PAST START
11
14
2
5
8
Revision 0.3 (10-26-04)

Related parts for LPC47N237-MD