MAX5980GTJ+T Maxim Integrated, MAX5980GTJ+T Datasheet - Page 32

no-image

MAX5980GTJ+T

Manufacturer Part Number
MAX5980GTJ+T
Description
Power Switch ICs - POE / LAN 0-16V Hot-Swap Controller
Manufacturer
Maxim Integrated
Datasheet

Specifications of MAX5980GTJ+T

Rohs
yes
Number Of Switches
Quad
Off Time (max)
0.1 ms
Operating Supply Voltage
32 V to 60 V
Maximum Operating Temperature
+ 105 C
Mounting Style
SMD/SMT
Maximum Power Dissipation
2758.6 mW
Minimum Operating Temperature
- 40 C
Operating Supply Current
5 mA
Quad, IEEE 802.3at/af PSE Controller
for Power-over-Ethernet
Table 9. Detect Event Register
Table 10. Fault Event Register
The Detect Event register (R04h/R05h, Table 9) records
detection/classification events for the port. On power-up
or after a reset condition, the Detect Event register is set
to a default value of 00h. DET_ and CLS_ are set high
whenever detection/classification is completed on the
corresponding port. As with the other event registers,
the Detect Event register has two addresses. When read
through the R04h address, the content of the register
is left unchanged. When read through the CoR R05h
address, the register content is reset to the default state.
32
SYMBOL
SYMBOL
TCUT4
TCUT3
TCUT2
TCUT1
CLS4
CLS3
CLS2
CLS1
DET4
DET3
DET2
DET1
DIS4
DIS3
DIS2
DIS1
ADDRESS =
ADDRESS =
Detect Event Register (R04h/R05h)
BIT NO.
BIT NO.
7
6
5
4
3
2
1
0
7
6
5
4
3
2
1
0
TYPE
TYPE
04h
06h
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
TYPE
TYPE
CoR
CoR
CoR
CoR
CoR
CoR
CoR
CoR
CoR
CoR
CoR
CoR
CoR
CoR
CoR
CoR
05h
07h
Classification completed on port 4
Classification completed on port 3
Classification completed on port 2
Classification completed on port 1
Detection completed on port 4
Detection completed on port 3
Detection completed on port 2
Detection completed on port 1
DC load disconnect timeout on port 4
DC load disconnect timeout on port 3
DC load disconnect timeout on port 2
DC load disconnect timeout on port 1
Overcurrent disconnect timeout on port 4
Overcurrent disconnect timeout on port 3
Overcurrent disconnect timeout on port 2
Overcurrent disconnect timeout on port 1
The Fault Event register (R06h/R07h, Table 10) records
port DC load and overcurrent disconnect timeout events.
On power-up or after a reset condition, the Fault Event
register is set to a default value of 00h. DIS_ is set to 1
whenever a port shuts down due to a DC load discon-
nect event. TCUT_ is set to 1 when a port shuts down
due to an extended overcurrent event after a success-
ful startup. As with the other events registers, the Fault
Event register has two addresses. When read through
the R06h address, the content of the register is left
unchanged. When read through the CoR R07h address,
the register content is reset to the default state.
DESCRIPTION
DESCRIPTION
Fault Event Register (R06h/R07h)