MAX5980GTJ+T Maxim Integrated, MAX5980GTJ+T Datasheet - Page 45

no-image

MAX5980GTJ+T

Manufacturer Part Number
MAX5980GTJ+T
Description
Power Switch ICs - POE / LAN 0-16V Hot-Swap Controller
Manufacturer
Maxim Integrated
Datasheet

Specifications of MAX5980GTJ+T

Rohs
yes
Number Of Switches
Quad
Off Time (max)
0.1 ms
Operating Supply Voltage
32 V to 60 V
Maximum Operating Temperature
+ 105 C
Mounting Style
SMD/SMT
Maximum Power Dissipation
2758.6 mW
Minimum Operating Temperature
- 40 C
Operating Supply Current
5 mA
Table 39. Port GPMD Register
The High-Power Enable register (R44h, Table 38) is
used to enable the high-power features on the ports.
On power-up or after a reset condition, if AUTO = 1, this
register is set to a default value of 0Fh. If AUTO = 0, it
is set to 00h. Set HP_EN_ to 1 to enable the use of the
high-power features found in R46h–R58h.
The Port GPMD registers (Table 39) are used to enable
the legacy high-capacitance PD detection and to enable
2-event classification for the corresponding port. On a
power-up or after a reset condition, these registers are
set to a default value of 94h. The status of the LEGACY
input on power-up or reset is latched into the LEG_EN_
bit. Set LEG_EN_ to 1 to enable, and 0 to disable, the
legacy high-capacitance detection for the correspond-
Table 38. High-Power Enable Register
Port GPMD Register (R46h, R4Bh, R50h, and R55h)
PONG_EN_
ADDRESS = 46h, 4Bh, 50h, 55h
SYMBOL
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
LEG_EN_
SYMBOL
Reserved
Reserved
Reserved
Reserved
HP_EN4
HP_EN3
HP_EN2
HP_EN1
ADDRESS = 44h
High-Power Enable Register (R44h)
BIT NO.
BIT NO.
7
6
5
4
3
2
1
0
7
6
5
4
3
2
1
0
Quad, IEEE 802.3at/af PSE Controller
TYPE
TYPE
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Set to 1 to enable legacy capacitance detection on the corresponding port
Set to 1 to enable 2-event classification on the corresponding port
Reserved
Reserved
Reserved
Reserved
Set to 1 to enable high-power features on port 4
Set to 1 to enable high-power features on port 3
Set to 1 to enable high-power features on port 2
Set to 1 to enable high-power features on port 1
for Power-over-Ethernet
ing port. Set PONG_EN_ to 1 to enable, and 0 to disable,
2-event classification.
The Port ICUT registers (Table 40) are used to set the
overcurrent SENSE_ voltage threshold for the corre-
sponding port. On power-up or after a reset condition,
if AUTO = 1, these registers are set to a default value of
D4h. If AUTO = 0, it is set to 14h. To calculate the over-
current setting, take decimal value of ICUT[5:0] multiplied
times 37.5mA for CUTRNG = 0, and multiplied times
18.75mA for CUTRNG = 1 (default). Multiply the result by
the value of the SENSE_ resistor (0.25I) to find the over-
current SENSE_ voltage threshold. Double the resulting
values when calculating Class 5 overcurrent thresholds.
DESCRIPTION
DESCRIPTION
(R47h, R4Ch, R51h, and R56h)
Port Overcurrent Register
45

Related parts for MAX5980GTJ+T