US38024-BAG1 Renesas Electronics America, US38024-BAG1 Datasheet - Page 322

no-image

US38024-BAG1

Manufacturer Part Number
US38024-BAG1
Description
DEV EVALUATION KIT H8/38024
Manufacturer
Renesas Electronics America
Series
H8®r
Type
MCUr
Datasheet

Specifications of US38024-BAG1

Contents
2G (Second-generation) Evaluation Board, HEW debugger support, Cable and CD-ROM
For Use With/related Products
H8/38024
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Section 9 Timers
When the pin function is switched and an edge is generated in the input capture input signal, if this
edge matches the edge selected by the input capture interrupt select (IIEGS) bit, the interrupt
request flag will be set to 1. The interrupt request flag should therefore be cleared to 0 before use.
Figure 9.15 shows the procedure for port mode register manipulation and interrupt request flag
clearing. When switching the pin function, set the interrupt-disabled state before manipulating the
port mode register, then, after the port mode register operation has been performed, wait for the
time required to confirm the input capture input signal as an input capture signal (at least two
system clocks when the noise canceler is not used; at least five sampling clocks when the noise
canceler is used), before clearing the interrupt enable flag to 0. There are two ways of preventing
interrupt request flag setting when the pin function is switched: by controlling the pin level so that
the conditions shown in tables 9.14 and 9.15 are not satisfied, or by setting the opposite of the
generated edge in the IIEGS bit in TMG.
Rev. 8.00 Mar. 09, 2010 Page 300 of 658
REJ09B0042-0800
Figure 9.15 Port Mode Register Manipulation and Interrupt Enable Flag Clearing
Clear interrupt request flag to 0
Manipulate port mode register
* TMIG confirmation time
Clear I bit in CCR to 0
Set I bit in CCR to 1
Disable interrupts. (Interrupts can also be disabled by
manipulating the interrupt enable bit in interrupt enable
register 2.)
After manipulating the port mode register, wait for the
TMIG confirmation time * (at least two system clocks when
the noise canceler is not used; at least five sampling
clocks when the noise canceler is used), then clear the
interrupt enable flag to 0.
Enable interrupts
Procedure