EP3C25U256I7 Altera, EP3C25U256I7 Datasheet - Page 12

IC CYCLONE III FPGA 25K 256 UBGA

EP3C25U256I7

Manufacturer Part Number
EP3C25U256I7
Description
IC CYCLONE III FPGA 25K 256 UBGA
Manufacturer
Altera
Series
Cyclone® IIIr

Specifications of EP3C25U256I7

Number Of Logic Elements/cells
24624
Number Of Labs/clbs
1539
Total Ram Bits
608256
Number Of I /o
156
Voltage - Supply
1.15 V ~ 1.25 V
Mounting Type
Surface Mount
Operating Temperature
-40°C ~ 100°C
Package / Case
256-UBGA
Family Name
Cyclone III
Number Of Logic Blocks/elements
24624
# I/os (max)
156
Frequency (max)
437.5MHz
Process Technology
65nm
Operating Supply Voltage (typ)
1.2V
Logic Cells
24624
Ram Bits
608256
Operating Supply Voltage (min)
1.15V
Operating Supply Voltage (max)
1.25V
Operating Temp Range
-40C to 100C
Operating Temperature Classification
Industrial
Mounting
Surface Mount
Pin Count
256
Package Type
UFBGA
For Use With
544-2370 - KIT STARTER CYCLONE III EP3C25
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Number Of Gates
-
Lead Free Status / Rohs Status
Not Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EP3C25U256I7
Manufacturer:
Altera
Quantity:
10 000
Part Number:
EP3C25U256I7N
Manufacturer:
ALTERA
Quantity:
220
Part Number:
EP3C25U256I7N
Manufacturer:
Altera
Quantity:
10 000
Part Number:
EP3C25U256I7N
Manufacturer:
ALTERA
0
1–2
Cyclone III Device Handbook, Volume 2
1
Table 1–1. Cyclone III Devices Absolute Maximum Ratings
Maximum Allowed Overshoot or Undershoot Voltage
During transitions, input signals may overshoot to the voltage listed in
undershoot to –2.0 V for a magnitude of currents less than 100 mA and for periods
shorter than 20 ns.
the duration of the overshoot voltage as a percentage over the lifetime of the device.
The maximum allowed overshoot duration is specified as percentage of high-time
over the lifetime of the device.
A DC signal is equivalent to 100% duty cycle. For example, a signal that overshoots to
4.2 V can only be at 4.2 V for 10.74% over the lifetime of the device; for device lifetime
of 10 years, this amounts to 10.74/10ths of a year.
I
V
V
T
T
Note to
(1) Supply voltage specifications apply to voltage readings taken at the device pins with respect to ground, not at the
OUT
S TG
J
Symbol
ES DHBM
ES DCDM
power supply.
Table
DC output current, per pin
Electrostatic discharge voltage using the human
body model
Electrostatic discharge voltage using the
charged device model
Storage temperature
Operating junction temperature
1–1:
Table 1–2
Parameter
lists the maximum allowed input overshoot voltage and
(Note 1)
Chapter 1: Cyclone III Device Data Sheet
Min
–25
–65
–40
© January 2010 Altera Corporation
(Part 2 of 2)
±2000
±500
Max
150
125
Electrical Characteristics
40
Table 1–2
Unit
mA
°C
°C
V
V
and