EP3C25U256I7 Altera, EP3C25U256I7 Datasheet - Page 47

IC CYCLONE III FPGA 25K 256 UBGA

EP3C25U256I7

Manufacturer Part Number
EP3C25U256I7
Description
IC CYCLONE III FPGA 25K 256 UBGA
Manufacturer
Altera
Series
Cyclone® IIIr

Specifications of EP3C25U256I7

Number Of Logic Elements/cells
24624
Number Of Labs/clbs
1539
Total Ram Bits
608256
Number Of I /o
156
Voltage - Supply
1.15 V ~ 1.25 V
Mounting Type
Surface Mount
Operating Temperature
-40°C ~ 100°C
Package / Case
256-UBGA
Family Name
Cyclone III
Number Of Logic Blocks/elements
24624
# I/os (max)
156
Frequency (max)
437.5MHz
Process Technology
65nm
Operating Supply Voltage (typ)
1.2V
Logic Cells
24624
Ram Bits
608256
Operating Supply Voltage (min)
1.15V
Operating Supply Voltage (max)
1.25V
Operating Temp Range
-40C to 100C
Operating Temperature Classification
Industrial
Mounting
Surface Mount
Pin Count
256
Package Type
UFBGA
For Use With
544-2370 - KIT STARTER CYCLONE III EP3C25
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Number Of Gates
-
Lead Free Status / Rohs Status
Not Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EP3C25U256I7
Manufacturer:
Altera
Quantity:
10 000
Part Number:
EP3C25U256I7N
Manufacturer:
ALTERA
Quantity:
220
Part Number:
EP3C25U256I7N
Manufacturer:
Altera
Quantity:
10 000
Part Number:
EP3C25U256I7N
Manufacturer:
ALTERA
0
Chapter 2: Cyclone III LS Device Data Sheet
Electrical Characteristics
Table 2–3. Cyclone III LS Devices Recommended Operating Conditions
© December 2009
V
V
V
V
C CINT
C CIO
C CA
C CD_P LL
Symbol
(3)
(3),
(3)
(3)
(6)
Supply voltage for internal logic
Supply voltage for output buffers, 3.3-V
operation
Supply voltage for output buffers, 3.0-V
operation
Supply voltage for output buffers, 2.5-V
operation
Supply voltage for output buffers, 1.8-V
operation
Supply voltage for output buffers, 1.5-V
operation
Supply voltage for output buffers, 1.2-V
operation
Supply (analog) voltage for PLL regulator
Supply (digital) voltage for PLL
Altera Corporation
Figure 2–1
example, overshoot voltage is shown in red and is present on the input pin of the
Cyclone III LS device at over 4.1 V but below 4.2 V. From
of 4.1 V, the percentage of high time for the overshoot can be as high as 31.97% over a
10-year period. Percentage of high time is calculated as ([delta T]/T) × 100. This
10-year period assumes the device is always turned on with 100% I/O toggle rate and
50% duty cycle signal. For lower I/O toggle rates and situations in which the device is
in an idle state, lifetimes are increased.
Figure 2–1. Cyclone III LS Devices Overshoot Duration
Recommended Operating Conditions
This section lists the functional operation limits for AC and DC parameters for
Cyclone III LS devices.
The steady-state voltage and current values expected from Cyclone III LS devices are
provided in
Parameter
shows the methodology to determine the overshoot duration. In this
Table
2–3. All supplies must be strictly monotonic without plateaus.
4.2 V
4.1 V
3.3 V
ΔT
Conditions
(Note 1)
T
,
(2)
(Part 1 of 2)
3.135
2.375
1.425
2.375
1.15
2.85
1.71
1.14
1.15
Min
Table
Cyclone III Device Handbook, Volume 2
2–1, for an overshoot
Typ
1.2
3.3
3.0
2.5
1.8
1.5
1.2
2.5
1.2
3.465
2.625
1.575
2.625
Max
1.25
3.15
1.89
1.26
1.25
Unit
V
V
V
V
V
V
V
V
V
2–3

Related parts for EP3C25U256I7