Specifications of EP3C25U256I7
Number Of Logic Elements/cells
24624
Number Of Labs/clbs
1539
Total Ram Bits
608256
Number Of I /o
156
Voltage - Supply
1.15 V ~ 1.25 V
Mounting Type
Surface Mount
Operating Temperature
-40°C ~ 100°C
Package / Case
256-UBGA
Family Name
Cyclone III
Number Of Logic Blocks/elements
24624
# I/os (max)
156
Frequency (max)
437.5MHz
Process Technology
65nm
Operating Supply Voltage (typ)
1.2V
Logic Cells
24624
Ram Bits
608256
Operating Supply Voltage (min)
1.15V
Operating Supply Voltage (max)
1.25V
Operating Temp Range
-40C to 100C
Operating Temperature Classification
Industrial
Mounting
Surface Mount
Pin Count
256
Package Type
UFBGA
For Use With
544-2370 - KIT STARTER CYCLONE III EP3C25
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Number Of Gates
-
Lead Free Status / Rohs Status
Not Compliant
Available stocks
Company
Part Number
Manufacturer
Quantity
Price
Company:
Part Number:
EP3C25U256I7N
Manufacturer:
ALTERA
Quantity:
220
2–6
Cyclone III Device Handbook, Volume 2
OCT calibration is automatically performed at device power-up for OCT enabled
I/Os.
Table 2–7
Table 2–7. Cyclone III LS Devices Series OCT with Calibration at Device Power-Up Specifications
OCT resistance may vary with the variation of temperature and voltage after
power-up calibration. Use
resistance considering the variations after power-up calibration.
Table 2–8
temperature.
Table 2–8. Cyclone III LS Devices OCT Variation After Calibration at Device Power-Up
Series Termination with
power-up calibration
Note to
(1) Use this table to calculate the final OCT resistance with the variation of temperature and voltage.
Description
Nominal Voltage
Table
lists the OCT calibration accuracy at device power-up.
lists the percentage change of the OCT resistance with voltage and
2–8:
3.0
2.5
1.8
1.5
1.2
V
CCIO
Table 2–8
3.0
2.5
1.8
1.5
1.2
(V)
Commercial Max
and
dR/dT (%/°C)
0.262
0.234
0.219
0.199
0.161
Equation 2–1
±10
±10
±10
±10
±10
Calibration Accuracy
Chapter 2: Cyclone III LS Device Data Sheet
to determine the final OCT
© December 2009 Altera Corporation
Industrial Max
±10
±10
±10
±10
±10
dR/dV (%/mV)
Electrical Characteristics
–0.026
–0.039
–0.086
–0.136
–0.288
(Note 1)
Unit
%
%
%
%
%