MSO-0008P-012

Manufacturer Part NumberMSO-0008P-012
DescriptionSocket, Relay; 8 Pin Octal
ManufacturerNCC
TypeOctal
MSO-0008P-012 datasheet
 

Specifications of MSO-0008P-012

Number Of Contacts8Time Range0.05 Sec. to 999 Min.
Output Rating10 A @ 240 VAC Max.; 100 mA @ 5 VDC Min.Operating Temperature–23°C to +55°C
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
Page 51
52
Page 52
53
Page 53
54
Page 54
55
Page 55
56
Page 56
57
Page 57
58
Page 58
59
Page 59
60
Page 60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
Page 51/114

Download datasheet (5Mb)Embed
PrevNext
Resistance Sensors
Models NS210 and NS211
FEATURES
100% functionally tested
Solid state sensing circuitry
Isolated UL Class ll sensing voltage
1/4” male fast-ons for circuit connection
Conformal coating to protect circuit
from harsh environments
File #E61377
Operating Logic: Assuming an empty tank,
upon application of voltage to the system,
the fill output is turned on and the heat-
er output is off. As the liquid fills the tank,
and when it reaches the low probe (above
heater), the heater output is turned on. The
level will rise until it reaches the high probe
causing the fill output to turn off. As liquid
is removed from the tank, 2 to 4 seconds
after it breaks contact with the high probe,
the fill output is turned on and stays on until
the liquid reaches the high probe. This time
delay eliminates fill output chatter if the liq-
uid is splashing.
If the tank is non-conductive, a third
(common) probe must be installed at a level
where it will always be submerged.
ORDERING INFORMATION
LOGIC TYPE
Pump Up
Pump Up
Pump Up
Pump Up
ACCESSORY
Probe Holder with Ground
Probe, 6” Long, 1/4” Dia., S.S.
Probe, 12” Long, 1/4” Dia., S.S.
Probe, 24” Long, 1/4” Dia., S.S.
Probe Assembly, Plastic Body
AMETEK National Controls Corp. • 1725 Western Drive • West Chicago, Illinois 60185 • Tel: 800-323-2593 • 630-231-5900 • FAX: 630-231-1377 • www.nationalcontrols.com
LIQUID LEVEL CONTROL SERIES
(Pump Up Logic with Heater Burn Out Protection)
SPECIFICATIONS
CONTROL TYPE
On/Off Resistance Sensing:
On low probe: probe resistance below set
point activates heater output
On high probe: probe resistance above set
point activates fill output after a 2 to 4 sec.
delay
Sensing Voltage: 15 VAC, max. RMS
Sensing Current: 2 mA, max. RMS
Sensitivity Adjustment: Factory set at
50 K ohms ±10%
INPUT
Operating Voltage: 24, 120, 240 VAC, ±10%
Power Consumption: 3.0 VA max.
Frequency: 50/60 Hz
OUTPUT
Type: Relay contacts, switch loads to L1
Rating: 5 A resistive at 240 VAC
Life:
Mechanical: 5,000,000 cycles
Electrical: 100,000 min. at full load
PROTECTION
Isolation: 1500 VAC between probe and other
terminals
MECHANICAL
Terminations: 1/4” x .032” male fast-ons
Mounting: 4 - .141” dia. mounting holes
ENVIRONMENTAL
Operating Temperature: 0°C to 55°C
INPUT VOLTAGE
PART NUMBER
24 VAC
LNC-NS210-024
120 VAC
LNC-NS210-120
240 VAC
LNC-NS210-240
120 VAC
LNC-NS211-120
PART NUMBER
LLH-11383-010
LLP-06.00-OSS
LLP-12.00-OSS
LLP-24.00-OSS
LLP-001/2-011
2-5
NS210
1.25
Input
Voltage
Low
Light
Heat
Fill
3.50
4.00
(5) .14 Dia
Mounting Holes
(3672-1)
4.00
NS211
3.50
.25
HEAT
FILL
Input
Voltage
PROBES
L
H C
To Probes
and Tank
(4) .14 Dia
Mounting Holes
(3672-2)
To Level Contro l
L H
C
Heating
Element
To conductive
tank
High Probe
Low Probe
Typical Probe Connection