MSO-0008P-012 NCC, MSO-0008P-012 Datasheet - Page 83

no-image

MSO-0008P-012

Manufacturer Part Number
MSO-0008P-012
Description
Socket, Relay; 8 Pin Octal
Manufacturer
NCC
Type
Octalr
Datasheet

Specifications of MSO-0008P-012

Number Of Contacts
8
Time Range
0.05 Sec. to 999 Min.
Output Rating
10 A @ 240 VAC Max.; 100 mA @ 5 VDC Min.
Operating Temperature
–23°C to +55°C
AMETEK National Controls Corp. • 1725 Western Drive • West Chicago, Illinois 60185 • Tel: 800-323-2593 • 630-231-5900 • FAX: 630-231-1377 • www.nationalcontrols.com
SPECIFICATIONS
CORE-10
INPUTS
Supply: 100-240 VAC, 50/60Hz, 4 VA max. at
240VAC without loads
Fuse: 3A fast, 5x20 mm
 Pressure Sensor Input: 4 to 20 mA, sink/
source, programmable 10.0”, 15.0”, 25.0” w.c.
 Pressure Switch Input: Dry contact, 4 mA at
13 VDC max.
Cycle Down Switch Input: Dry contact, 4 mA at
13 VDC max.
OUTPUTS
Solenoid Outputs: 10
Output Type: Triac
Output Rating: 150 VA (at max. ON, min. OFF, 1
output selected)
Timing Accuracy: -2mS, +10 mS or +1% (which-
ever is greater), ON-time synchronized to AC line
Alarm Relay: Form-A contact, 3A at 250
VAC/30 VDC, programmable normally open or
normally closed
DISPLAY INDICATORS
3-digit 7-segment LED display, 0.56 in. red
Program Parameters/Display Status/CANbus
Status: 17 green LEDs
Alarm: 1 red/yellow LED
Output Status: 1 red/green LED
PARAMETER RANGES
ON-Time: 0.050-600 sec.
OFF-Time: 1-999 sec.
Timing Accuracy: -2 ms, +10 ms or +1% (which-
ever is greater), ON-time synchronized to AC line
Cycle Down Cycles: 1-20, none
Cycle Down Delay: 60-600 sec.
 P High Setpoint: 0-10/15/25” w.c., none
 P Low Setpoint: 0-10/15/25” w.c., none
 P High Alarm: 0-10/15/25” w.c., none
 P Low Alarm: 0-10/15/25” w.c., none
COMMUNICATIONS
Type: CANbus architecture
Terminations: Screw terminals, #12 to #28 AWG,
finger safe
ENVIRONMENTAL
Operating Temperature: -40°F to +150°F (-40°C
to +65°C)
Environmental Protection: Conformal coating
for humidity and vibration
EXPANDER-10 SPECIFICATIONS
INDICATORS
Solenoid Pulse Indication: 10 green LEDs
CANbus Status: 1 green LED
Output Status1: 1 red/green LED
OUTPUTS
Solenoids: 10 per Expansion Module
Output Type: Triac
Output Rating: 150 VA (at max. ON, min. OFF, 1
output selected)
Timing Accuracy: -2 ms, +10 ms or +1% (which-
ever is greater), ON-time synchronized to AC line
ALARM
POWER
CORE-10
EXPANDER-10
N a t i o n a l C o n t r o l s C o r
ALARM
GND
L1
L2
GND
Cycle Down Delay Time
L1
L2
Cycle Down Cycles
100-240 VAC
Solenoid Off Time
p.
100-240 VAC
SHOWS "SINK"
SHOWS "SOURCE"
.
3.15A
E65038
.25 DIA. HOLE (4 PL.)
(6.35)
Solenoid On Time
Solenoid Output
Pressure
+
Output
Alarm
SENSOR
SENSOR
6.875 (174.63)
6.875 (174.63)
P
P
Run
DUST COLLECTOR CONTROLS
Standby
Output Pulsing
Cycle Down
Alarm
N.O.
Pressure High Set Point
N.C.
Pressure Low Set Point
Pressure High Alarm Point
Pressure Low Alarm Point
OUTPUTS TO 120 OR 240V AC AIR SOLENOIDS
L2 TERMINALS ARE INTERNALLY CONNECTED TO L2 SUPPLY
2
2
1
1
OUTPUTS TO 120 OR 240V AC AIR SOLENOIDS
L2 TERMINALS ARE INTERNALLY CONNECTED TO L2 SUPPLY
Caution:
1. Do not mount controls in high vibration areas with-
out shock mounts.
2. Do not mount controls in areas of high dust or cor-
rosive atmospheres without a protective enclosure.
3 Do not use a converter or inverter for the power
source.
4. Do not mount control in high transient voltage
areas without an isolation transformer.
5. Do not leave control box open.
6. Do not allow a local repair shop to repair the con-
trols, as we employ some very sophisticated compo-
nents that could be further damaged. For service, call
us directly: 800-323-2593.
.313 (7.95)
.313 (7.95)
.25 DIA. HOLE (4 PL.)
(6.35)
TWISTED PAIR COMMUNICATIONS CABLE
TO EXPANSION UNITS (IF USED)
TWISTED PAIR COMMUNICATIONS CABLE
TO MAIN CONTROLLER AND OTHER
EXPANSION UNITS (IF USED)
(12.7)
.50
(38.1)
1.50
4-11

Related parts for MSO-0008P-012