MSO-0008P-012 NCC, MSO-0008P-012 Datasheet - Page 56

no-image

MSO-0008P-012

Manufacturer Part Number
MSO-0008P-012
Description
Socket, Relay; 8 Pin Octal
Manufacturer
NCC
Type
Octalr
Datasheet

Specifications of MSO-0008P-012

Number Of Contacts
8
Time Range
0.05 Sec. to 999 Min.
Output Rating
10 A @ 240 VAC Max.; 100 mA @ 5 VDC Min.
Operating Temperature
–23°C to +55°C
2-10
AMETEK National Controls Corp. • 1725 Western Drive • West Chicago, Illinois 60185 • Tel: 800-323-2593 • 630-231-5900 • FAX: 630-231-1377 • www.nationalcontrols.com
Resistance Sensors
Model NS157
FEATURES
Operating Logic: The output relay is acti-
vated when liquid touches the probe. As the
liquid level drops below the probe, the relay
is deactivated.
(common) probe must be installed at a level
where it will always be submerged.
ORDERING INFORMATION
Probe Holder with Ground
Probe, 6” Long, 1/4” Dia., S.S.
Probe, 12” Long, 1/4” Dia., S.S.
Probe, 24” Long, 1/4” Dia., S.S.
Probe Assembly, Plastic Body
Low Water Detect
Low Water Detect
If the tank is non-conductive, a second
100% functionally tested
Solid state sensing circuitry
Isolated UL Class ll sensing voltage
1/4” male fast-ons for circuit connection
Conformal coating to protect circuit
from harsh environments
LIQUID LEVEL CONTROL SERIES
ACCESSORY
LOGIC TYPE
File #E61377
INPUT VOLTAGE
PART NUMBER
LLP-06.00-OSS
LLP-12.00-OSS
LLP-24.00-OSS
LLH-11383-010
LLP-001/2-011
120 VAC
240 VAC
(Low Water Detect Logic)
SPECIFICATIONS
CONTROL TYPE
On/Off Resistance Sensing: Probe resistance
below set point activates output relay
Sensing Voltage: 20 VAC, max. RMS
Sensing Circuit: 2 mA, max. RMS
Sensitivity Adjustment: Factory set at
50 K ohms ±10%
INPUT
Operating Voltage: 120, 240 VAC, ±10%
Power Consumption: 3.0 VA max.
Frequency: 50/60 Hz
OUTPUT
Type: SPDT relay, isolated contacts
Rating: 5 A resistive at 120 VAC 100 mA at
5 VDC min. load current
Life:
Mechanical: 2,000,000 cycles
Electrical: 100,000 min. at full load
PROTECTION
Isolation: 1500 VAC between probe and other
terminals
MECHANICAL
Terminations: 1/4” x .032” male fast-ons
Mounting: 4 -.141” dia. mounting holes
ENVIRONMENTAL
Operating Temperature: 0°C to 70°C
LNC-NS157-120
LNC-NS157-240
PART NUMBER
075
.187 X .020 MALE
FAST-ON (3 PL)
OUTPUT WHEN 120V INPUT IS USED
MUST USE COM TO 240 V OUTPUT
NOTE: MUST USE COM TO 120 V
1.40
WHEN 240 V INPUT IS USED
COM
INPUT VOLTAGE
COM
.250 X .032 MALE
FAST-ON (6 PL)
2.80
120 VAC
240 VAC
120V
(RED LED)
120V
IDLE
240V
240V
LOAD