MSO-0008P-012 NCC, MSO-0008P-012 Datasheet - Page 62

no-image

MSO-0008P-012

Manufacturer Part Number
MSO-0008P-012
Description
Socket, Relay; 8 Pin Octal
Manufacturer
NCC
Type
Octalr
Datasheet

Specifications of MSO-0008P-012

Number Of Contacts
8
Time Range
0.05 Sec. to 999 Min.
Output Rating
10 A @ 240 VAC Max.; 100 mA @ 5 VDC Min.
Operating Temperature
–23°C to +55°C
AMETEK National Controls Corp. • 1725 Western Drive • West Chicago, Illinois 60185 • Tel: 800-323-2593 • 630-231-5900 • FAX: 630-231-1377 • www.nationalcontrols.com
3-4
Digital Temperature Controller
TC142 Series
FEATURES
The Model TC142 is a Digital Temperature
Controller. The controller uses a Type
K thermocouple and is microprocessor
controlled. The regulation temperature can
be set in one degree increments within
specified limits. Hysteresis, Offset and
Fahrenheit or Celsius are selected via front
panel switches. The HEAT ON light indicates
output relay activation. The regulation
temperature is normally shown on the digital
display. To view the sensed temperature,
press the TEMP button. The control has
diagnostic messages for open probe and
memory failure.
Setting Regulation Point: Press the PROG
button momentarily. The display will flash
SET and PNT briefly then flash the set-
point value. The
be used to adjust the temperature regulat-
ing setpoint. Press the PROG button again
to cause the control to regulate to the new
setpoint. To view or change other functions
while in program mode, press ADV button
to scroll to that function.
Setting Hysteresis: The turn-on and turn-
off temperature around a setpoint can be
separately adjusted to ±20°F. Press and
hold the PROG button for .5 second. Scroll
to DEAD BAND using the ADV button. The
display will alternate between ON and the
turn-on value. The
now be used to change this value. Press the
Compact design
Easy-to-read 4-digit LED display
Temperature display in Fahrenheit or
Celsius
Non-volatile storage of programmed
parameters
Watchdog timer ensures reliability
4-button, moisture-resistant keyboard
using snap-action sealed switches
Diagnostic messages for fault condi-
tions
Front panel keyboard programming of
time and temperature
HEAT ON indicator
Accurate and durable thermocouple
temperature sensing
Convenient operating voltage ranges
Heavy duty stainless steel front panel
TEMPERATURE MONITORS/CONTROLS
File #E104595
and
and
buttons can now
buttons can
ORDERING INFORMATION
*All transformer wires are 8” long: 120V Primary Black/White; 220V Primary Black/Black
ADV button again and the OFF value will be
displayed. The
be used to change the OFF value. Pressing
the PROG button again will return the con-
trol to normal operation and will store the
new settings. The hysteresis is set to -1°F,
+0°F as shipped from the factory.
Setting Offset: The displayed value can be
changed by ±20°F relative to actual sensed
temperature value. This feature corrects for
disparity of location of the probe and the
volumetric center of the heating chamber.
Press and hold the PROG button for .5 sec-
ond. Scroll to the offset function using the
ADV button. The display will flash OFF and
SET briefly then will flash the offset value.
At this point, the
be used to adjust the offset. Pressing the
TEMP button programs the control for the
new value. The offset is set to 0 as shipped
from the factory.
Diagnostic Messages: An open probe will
cause the digital display to show PROB and
will disable the output until input voltage is
removed and re-applied. If a memory loss or
failure occurs, the digital display will show
FAIL and the output will be disabled. Input
voltage should be removed and re-applied.
If the FAIL message is gone, recheck pro-
grammed parameters and resume opera-
tion. If the FAIL message reappears, contact
the factory for service.
Type K Thermocouple, Bead Tip Probe, 6’
Type K Thermocouple, Perforated Probe, 24”
Type K Thermocouple, Probe with 6’ Lead
Type Ke Thermocouple, Probe with 10’ Lead
Type K Thermocouple, Perforated Probe, 48”
Type K Thermocouple, Perforated Probe, 72”
Type K Thermocouple, Probe with Flange
Type K Thermocouple, Ring Lug Mount
Transformer - 120V, 60Hz Primary
Transformer - 240V, 50/60Hz Primary
INPUT VOLTAGE
198 to 242 VAC
90 to 135 VAC
18 to 28 VAC
and
ACCESSORY
and
buttons can now
buttons can
TNC-TC142-A010
TNC-TC142-A120
TNC-TC142-A220
B24-NO120-011
B24-NO220-011
ASP-CH/AL-011
ASP-CH/AL-013
ASP-CH/AL-016
ASP-CH/AL-017
ASP-CH/AL-018
ASP-CH/AL-019
ASP-CH/AL-020
ASP-CH/AL-021
PART NUMBER
PART NUMBER

Related parts for MSO-0008P-012