tmxf28155 ETC-unknow, tmxf28155 Datasheet - Page 286

no-image

tmxf28155

Manufacturer Part Number
tmxf28155
Description
Tmxf28155 Super Mapper 155/51 Mbits/s Sonet/sdh X28/x21 Ds1/e1
Manufacturer
ETC-unknow
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
tmxf281553BAL3C
Manufacturer:
DSP
Quantity:
5
155/51 Mbits/s SONET/SDH x28/x21 DS1/E1
12 28-Channel Framer Registers
The register in
digital section and the exchange termination (ET) as defined in ETS 300 233 section 9.3 and Table 2. These are
decoded from the A, Sa5, and Sa6 bits. The Sa6 code words are synchronized to the CRC-4 multiframe.
Table 394. FRM_PMLR13, Performance Monitor Link Register 13 (COR)
* See
286
Address*
0x8LP8C 15:14
Table 381
for values of L and P .
Bit
13
12
11
10
Table 394
9
8
7
6
5
4
3
2
1
0
FRM_FE_OP Defect FCET in the ET or FCDLd in the Digital Link Between V3
FRM_FE_N
FRM_FE_M Reception of AIS at V3 Reference Point of LT (Reaction to FCDL
FRM_FE_H
FRM_FE_G
FRM_FE_D
FRM_FE_C
FRM_FE_K
FRM_FE_E
FRM_FE_B
FRM_FE_A
FRM_FE_L
FRM_FE_F
FRM_FE_I
Name
provides a status indication of functional elements (FE) exchanged between the access
Reserved. Must write to 0.
and V3 or Defect FCDLu Between the V3 and V3. AIS.
Reception of AIS at V3 Reference Point of LT and FC4 Simulta-
neously. (0, 1, 1111.)
or FCET). (1, 1, 1111.)
LOS at Line Side of LT (FC1). AUXP.
Loss of Power at NT1 and LOS/LFA at TE Simultaneously. (1, 1,
1000.)
Loss of Power at NTT. (0, 1, 1000.)
Simultaneous FC3 and FC4. (0, 1, 1110.)
LOS/LFA at T Reference Point of NT1. (0, 1, 1100.)
LOS/LFA at V3 Reference Point of ET. (1, 0, 0000.)
LOS at Line Side of NT1 or at V3 Reference Point of LT Only. (1,
1, 1110.)
LOS/LFA at TE. (1, 1, 00xx.)
Unintentional Loopback. (x, 0, xxxx.)
Normal Operation of the ET. (x, 0, 0000.)
Normal Operation of the DS. (x, 1, 00xx.)
(continued)
(A, SA5, SA6[1:4])
Function
Agere Systems Inc.
May 2001
Default
Reset
00
0
0
0
0
0
0
0
0
0
0
0
0
0
0

Related parts for tmxf28155