M306N4FGTFP Renesas Electronics America, M306N4FGTFP Datasheet - Page 257

IC M16C MCU FLASH 100QFP

M306N4FGTFP

Manufacturer Part Number
M306N4FGTFP
Description
IC M16C MCU FLASH 100QFP
Manufacturer
Renesas Electronics America
Series
M16C™ M16C/6Nr
Datasheets

Specifications of M306N4FGTFP

Core Processor
M16C/60
Core Size
16-Bit
Speed
20MHz
Connectivity
CAN, I²C, IEBus, SIO, UART/USART
Peripherals
DMA, WDT
Number Of I /o
85
Program Memory Size
256KB (256K x 8)
Program Memory Type
FLASH
Ram Size
10K x 8
Voltage - Supply (vcc/vdd)
4.2 V ~ 5.5 V
Data Converters
A/D 26x10b; D/A 2x8b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
100-QFP
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
M306N4FGTFP
Manufacturer:
TI
Quantity:
3 001
Part Number:
M306N4FGTFP
Manufacturer:
RENESAS
Quantity:
36
Part Number:
M306N4FGTFP
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Part Number:
M306N4FGTFP
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
Part Number:
M306N4FGTFP#UKJ
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Part Number:
M306N4FGTFP#UKJ
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
M16C/6N Group (M16C/6N4)
Rev.2.40
REJ09B0009-0240
19.12 Return from Bus Off Function
19.13 Time Stamp Counter and Time Stamp Function
19.14 Listen-Only Mode
When the protocol controller enters bus off state, it is possible to make it forced return from bus off state by
setting the RetBusOff bit in the CiCTLR register (i = 0, 1) to 1 (force return from bus off). At this time, the
error state changes from bus off state to error active state. If the RetBusOff bit is set to 1, registers CiRECR
and CiTECR are initialized and the State_BusOff bit in the CiSTR register is set to 0 (CAN module is not in
error bus off state). However, registers of the CAN module such as CiCONR register and the content of
each slot are not initialized.
When the CiTSR register ( i = 0, 1) is read, the value of the time stamp counter at the moment is read. The
period of the time stamp counter reference clock is the same as that of 1 bit time that is configured by the
CiCONR register. The time stamp counter functions as a free run counter.
The 1 bit time period can be divided by 1 (undivided), 2, 4 or 8 to produce the time stamp counter reference
clock. Use the TSPreScale bit in the CiCTLR register to select the divide-by-n value.
The time stamp counter is equipped with a register that captures the counter value when the protocol
controller regards it as a successful reception. The captured value is stored when a time stamp value is
stored in a reception slot.
When the RXOnly bit in the CiCTLR register ( i = 0, 1) is set to 1, the module enters Listen-only mode.
In Listen-only mode, no transmission, such as data frames, error frames, and ACK response, is performed
to bus.
When Listen-only mode is selected, do not request the transmission.
Apr 14, 2006
page 233 of 376
19. CAN Module

Related parts for M306N4FGTFP