ADWPCIXRSKU20
Description
Manufacturer
Intel
Datasheet

Specifications of ADWPCIXRSKU20

Lead Free Status / Rohs Status
Supplier Unconfirmed
Power-Down
Soft-shutdown
Power cycle
Reset
Diagnostic Interrupt
PET Alert
Sensor feedback
IPMB message event
Fault LED action
Identification LED action
Platform Management
5.2.21.2
LAN alerts are sent as SNMP traps in ASF formatted Platform Event Traps (PET) to a specified
alert destination. The Alert over LAN feature is used to send either PET alerts or directed events
to a remote system management application, regardless of the state of the host’s operating
system.
LAN alerts may be sent over any of the LAN channels supported by a platform. LAN alerts can
be used by PEF to send out alerts to selected destination whenever an event matches an event
filter table entry. For more information on LAN alerts, see the IPMI specifications v1.5
5.2.22
The following tables are for the built-in and the external sensors for the platform. There is a
management controller locator record as a built-in SDR besides the given below.
mBMC sensors 01h – 08h are internal sensors to the mBMC and are used for event generation
only. These sensors are not for use with the ‘Get Sensor Reading’ IPMI command and may
return an error when read.
120
Action
mBMC Sensor Support
Alert over LAN
1
4
5
8
9
10
2
3
6
7
Priority
Yes
Yes
Yes
Yes
No
No
No
No
No
No
Delayed
Intel order number C91056-002
Table 57. PEF Action Priorities
PEF Action
OEM PEF Action
PEF Action
PEF Action
PEF Action
PEF Action
OEM PEF Action
OEM PEF Action
OEM PEF Action
OEM PEF Action
Type
Not executed if a power-down action was
also selected
Not executed if a power-down action was
also selected
Not executed if a power-down action was
also selected
Not executed if a power-down action was
also selected
When selected, always occurs immediately
after detection of a critical event.
When selected, always occurs immediately
after detection of a critical event.
When selected, always occurs immediately
after detection of a critical event.
When selected, always occurs immediately
after detection of a critical event, and is
stopped after the de-assertion of all critical
events that requested LED blinking.
When selected, always occurs immediately
after detection of a critical event.
Intel® Server Board SE7320VP2
Note
Revision 2.1