ADWPCIXRSKU20 Intel, ADWPCIXRSKU20 Datasheet - Page 122

no-image

ADWPCIXRSKU20

Manufacturer Part Number
ADWPCIXRSKU20
Description
Manufacturer
Intel
Datasheet

Specifications of ADWPCIXRSKU20

Lead Free Status / Rohs Status
Supplier Unconfirmed
Platform Management
5.3
The BIOS supports Console Redirection. The BIOS supports redirection of both video and
keyboard via a serial link (Serial A or Serial B). When console redirection is enabled, the local
(host server) keyboard input and video output are passed both to the local keyboard and video
connections, as well as to the remote console via the serial link. Keyboard inputs from both
sources are valid and video is displayed to both outputs. As an option, the system can be
operated without a keyboard or monitor attached to the host system and can run entirely from
the remote console. Setup and any other text-based utilities can be accessed through console
redirection.
The BIOS maps the setup values for Serial console redirection to the ACPI Serial Port Console
Redirection tables. BIOS Console Redirection terminates before giving control to an operating
system. The operating system is responsible for continuing the Console Redirection after that
point. BIOS console redirection is a text-based console and any graphical data, such as a logo,
is not redirected.
BIOS Console Redirection is intended to accomplish the implementation of VT-UTF8 console
redirection support in Intel
requirements set forth in the Microsoft Whistler WHQL requirements for headless operation of
servers, as well as maintain a necessary degree of backward compatibility with existing Intel
server BIOS products, and meet the architectural requirements of Intel server products currently
in development.
The server BIOS has a “console” that is intended to interact with a display and keyboard
combination. The BIOS displays data in the form of BIOS Setup screens, Boot Manager
screens, Power On Self Test (POST) informational messages and hotkey/escape sequence
action requests.
122
Console Redirection
Tach Fan 4
Tach Fan 5
Tach Fan 6
Tach Fan 7
Tach Fan 8
Tach Fan 9
Processor1 Fan
Processor2 Fan
Processor1 IERR
Processor2 IERR
Processor1 Thermal trip
Processor2 Thermal trip
Diagnostic Interrupt Button
Chassis Identify Button
Processor1 Thermal Control
Processor2 Thermal Control
®
server BIOS products. That implementation will meet the functional
Sensor Name
Intel order number C91056-002
1Dh
1Eh
1Fh
20h
21h
22h
23h
24h
25h
26h
27h
28h
29h
2Ah
2Bh
2Ch
Sensor #
Fault LED Action
Fault LED Action
Fault LED Action
Fault LED Action
Fault LED Action
Fault LED Action
Fault LED Action
Fault LED Action
Fault LED Action
Fault LED Action
NMI Pulse
ID LED Action
Fault LED Action
Fault LED Action
PEF Action
Intel® Server Board SE7320VP2
Revision 2.1