r4f2426 Renesas Electronics Corporation., r4f2426 Datasheet - Page 906

no-image

r4f2426

Manufacturer Part Number
r4f2426
Description
16-bit Single-chip Microcomputer H8s Family / H8s/2400 Series
Manufacturer
Renesas Electronics Corporation.
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
r4f24268NVFQV
Manufacturer:
Renesas Electronics America
Quantity:
135
Part Number:
r4f24268NVFQV
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Part Number:
r4f24268NVRFQV
Manufacturer:
Renesas Electronics America
Quantity:
135
Part Number:
r4f24268NVRFQV
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Part Number:
r4f24268NVZFQV
Manufacturer:
REA
Quantity:
150
Part Number:
r4f24268NVZFQV
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Part Number:
r4f24269NVFQV
Manufacturer:
Renesas Electronics America
Quantity:
135
Part Number:
r4f24269NVFQV
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Section 15 Serial Communication Interface (SCI, IrDA)
Rev. 1.00 Sep. 19, 2008 Page 878 of 1270
REJ09B0466-0100
No
No
Read receive data in RDR, and
clear RDRF flag in SSR to 0
PER ∨ FER ∨ ORER = 1?
Clear RE bit in SCR to 0
Read RDRF flag in SSR
Read ORER, PER, and
Figure 15.9 Sample Serial Reception Data Flowchart (1)
All data received?
FER flags in SSR
Start of reception
Initialization
RDRF = 1?
<End>
Yes
Yes
No
(Continued on next page)
Error handling
Yes
[1]
[2]
[4]
[5]
[3]
[1]
[2] [3]
[4]
[5]
SCI initialization:
The RxD pin is automatically
designated as the receive data
input pin.
break detection:
If a receive error occurs, read the
ORER, PER, and FER flags in
SSR to identify the error. After
performing the appropriate error
processing, ensure that the
ORER, PER, and FER flags are
all cleared to 0. Reception cannot
be resumed if any of these flags
are set to 1. In the case of a
framing error, a break can be
detected by reading the value of
the input port corresponding to
the RxD pin.
SCI status check and receive
data read :
Read SSR and check that RDRF
= 1, then read the receive data in
RDR and clear the RDRF flag to
0. Transition of the RDRF flag
from 0 to 1 can also be identified
by an RXI interrupt.
Serial reception continuation
procedure:
To continue serial reception,
before the stop bit for the current
frame is received, read the
RDRF flag, read RDR, and clear
the RDRF flag to 0. The RDRF
flag is cleared automatically
when the DMAC or DTC is
activated by an RXI interrupt and
the RDR value is read.
Receive error handling and

Related parts for r4f2426