Bit 0—Program (P): Selects program mode transition or clearing. Do not set the SWE, PSU,
ESU, EV, PV, or E bit at the same time.
20.5.2
Note: FLMCR2 is a read-only register, and should not be written to.
FLMCR2 is an 8-bit register used for flash memory operating mode control. FLMCR2 is
initialized to H'00 by a reset, and in hardware standby mode and software standby mode. When
on-chip flash memory is disabled, a read will return H'00.
Bit 7—Flash Memory Error (FLER): Indicates that an error has occurred during an operation
on flash memory (programming or erasing). When FLER is set to 1, flash memory goes to the
error-protection state.
Bits 6 to 0—Reserved: These bits always read 0.
Bit 0
P
0
1
Bit 7
FLER
0
1
Initial value:
Flash Memory Control Register 2 (FLMCR2)
Description
Program mode cleared
Transition to program mode
[Setting condition]
When FWE = 1, SWE = 1, and PSU = 1
Description
Flash memory is operating normally
Flash memory program/erase protection (error protection) is disabled
[Clearing condition]
Reset or hardware standby mode
An error has occurred during flash memory programming/erasing
Flash memory program/erase protection (error protection) is enabled
[Setting condition]
See section 20.8.3 Error Protection
R/W:
Bit:
FLER
R
7
0
R
6
0
R
5
0
R
4
0
Rev. 5.00 Sep 22, 2005 page 683 of 1136
R
3
0
R
2
0
REJ09B0257-0500
Section 20 ROM
R
1
0
(Initial value)
(Initial value)
R
0
0