DF70844AD80FPV Renesas Electronics America, DF70844AD80FPV Datasheet - Page 1010

IC SUPERH MCU FLASH 112LQFP

DF70844AD80FPV

Manufacturer Part Number
DF70844AD80FPV
Description
IC SUPERH MCU FLASH 112LQFP
Manufacturer
Renesas Electronics America
Series
SuperH® SH7080r
Datasheet

Specifications of DF70844AD80FPV

Core Size
32-Bit
Program Memory Size
256KB (256K x 8)
Core Processor
SH-2
Speed
80MHz
Connectivity
EBI/EMI, FIFO, I²C, SCI, SSU
Peripherals
DMA, POR, PWM, WDT
Number Of I /o
76
Program Memory Type
FLASH
Ram Size
16K x 8
Voltage - Supply (vcc/vdd)
3 V ~ 5.5 V
Data Converters
A/D 8x10b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
112-LQFP
No. Of I/o's
76
Ram Memory Size
16KB
Cpu Speed
80MHz
Digital Ic Case Style
LQFP
Supply Voltage Range
3V To 3.6V, 4.5V To 5.5V
Embedded Interface Type
I2C, SCI
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With
R0K570865S001BE - KIT STARTER FOR SH7086R0K570865S000BE - KIT STARTER FOR SH7086HS0005KCU11H - EMULATOR E10A-USB H8S(X),SH2(A)
Eeprom Size
-
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
DF70844AD80FPV
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Company:
Part Number:
DF70844AD80FPV
Quantity:
5 000
Section 19 A/D Converter (ADC)
Note:
Rev. 3.00 May 17, 2007 Page 952 of 1582
REJ09B0181-0300
Bit
5, 4
3
2 to 0
*
Bit Name
ADM[1:0]
CH[2:0]
ADCS
Writing 0 to this bit after reading it as 1 is clears the flag and is the only allowed way.
00
000
Initial
Value
0
R/W
R/W
R/W
R/W
Description
A/D Mode 1 and 0
Select the A/D conversion mode. 2-channel scan
mode is supported only by A/D modules 0 and 1. Do
not select 2-channel scan mode in A/D module 2.
00: Single mode
01: 4-channel scan mode
10: 8-channel scan mode
11: 2-channel scan mode
When changing the operating mode, first clear the
ADST bit to 0.
A/D Continuous Scan
Selects either single-cycle scan or continuous scan in
scan mode. This bit is valid only when scan mode is
selected.
0: Single-cycle scan
1: Continuous scan
When changing the operating mode, first clear the
ADST bit to 0.
Channel Select 2 to 0
Select analog input channels. See table 19.3.
When changing the operating mode, first clear the
ADST bit to 0.

Related parts for DF70844AD80FPV