Z8F042AHH020EG Zilog, Z8F042AHH020EG Datasheet - Page 162

IC ENCORE XP MCU FLASH 4K 20SSOP

Z8F042AHH020EG

Manufacturer Part Number
Z8F042AHH020EG
Description
IC ENCORE XP MCU FLASH 4K 20SSOP
Manufacturer
Zilog
Series
Encore!® XP®r
Datasheet

Specifications of Z8F042AHH020EG

Core Processor
Z8
Core Size
8-Bit
Speed
20MHz
Connectivity
IrDA, UART/USART
Peripherals
Brown-out Detect/Reset, LED, LVD, POR, PWM, Temp Sensor, WDT
Number Of I /o
17
Program Memory Size
4KB (4K x 8)
Program Memory Type
FLASH
Eeprom Size
128 x 8
Ram Size
1K x 8
Voltage - Supply (vcc/vdd)
2.7 V ~ 3.6 V
Data Converters
A/D 7x10b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 105°C
Package / Case
20-SSOP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
269-4156
Z8F042AHH020EG
PS022517-0508
Caution:
Follow the steps below for setting up the ADC and initiating continuous conversion:
1. Enable the desired analog input by configuring the GPIO pins for alternate function.
2. Write to the ADC Control Register to configure the ADC for continuous conversion.
3. When the first conversion in continuous operation is complete (after 5129 system
4. Thereafter, the ADC writes a new 10-bit data result to {ADCD_H[7:0],
5. To disable continuous conversion, clear the
This disables the digital input and output driver.
The bit fields in the ADC Control Register can be written simultaneously:
clock cycles, plus the 40 cycles for power-up, if necessary), the ADC control logic
performs the following operations:
ADCD_L[7:6]} every 256 system clock cycles. An interrupt request is sent to the
Interrupt Controller when each conversion is complete.
to 0.
In CONTINUOUS mode, ensure that ADC updates are limited by the input
signal bandwidth of the ADC and the latency of the ADC and its digital fil-
ter. Step changes at the input are not seen at the next output from the ADC.
The response of the ADC (in all modes) is limited by the input signal band-
width and the latency.
Write to the ANAIN[3:0] field to select one of the 5 analog input sources.
Set CONT to 1 to select continuous conversion.
Write to the VREF bit to enable or disable the internal voltage reference generator.
Set CEN to 1 to start the conversions.
CEN resets to 0 to indicate the first conversion is complete. CEN remains 0 for all
subsequent conversions in continuous operation.
An interrupt request is sent to the Interrupt Controller to indicate the conversion is
complete.
CONT
bit in the ADC Control Register
Z8 Encore! XP
Product Specification
Analog-to-Digital Converter
®
F0822 Series
149

Related parts for Z8F042AHH020EG