Z8F042AHH020EG Zilog, Z8F042AHH020EG Datasheet - Page 84

IC ENCORE XP MCU FLASH 4K 20SSOP

Z8F042AHH020EG

Manufacturer Part Number
Z8F042AHH020EG
Description
IC ENCORE XP MCU FLASH 4K 20SSOP
Manufacturer
Zilog
Series
Encore!® XP®r
Datasheet

Specifications of Z8F042AHH020EG

Core Processor
Z8
Core Size
8-Bit
Speed
20MHz
Connectivity
IrDA, UART/USART
Peripherals
Brown-out Detect/Reset, LED, LVD, POR, PWM, Temp Sensor, WDT
Number Of I /o
17
Program Memory Size
4KB (4K x 8)
Program Memory Type
FLASH
Eeprom Size
128 x 8
Ram Size
1K x 8
Voltage - Supply (vcc/vdd)
2.7 V ~ 3.6 V
Data Converters
A/D 7x10b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 105°C
Package / Case
20-SSOP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
269-4156
Z8F042AHH020EG
PS022517-0508
2. Write to the Timer High and Low Byte Registers to set the starting count value.
3. Write to the Timer Reload High and Low Byte Registers to set the Reload value.
4. If desired, enable the timer interrupt and set the timer interrupt priority by writing to
5. If using the Timer Output function, configure the associated GPIO port pin for the
6. Write to the Timer Control Register to enable the timer and initiate counting.
In ONE-SHOT mode, the system clock always provides the timer input. The timer period
is given by the following equation:
CONTINUOUS Mode
In CONTINUOUS mode, the timer counts up to the 16-bit Reload value stored in the
Timer Reload High and Low Byte Registers. The timer input is the system clock. Upon
reaching the Reload value, the timer generates an interrupt, the count value in the Timer
High and Low Byte Registers is reset to
Output alternate function is enabled, the Timer Output pin changes state (from Low to
High or from High to Low) upon timer Reload.
Follow the steps below for configuring a timer for CONTINUOUS mode and initiating the
count:
1. Write to the Timer Control Register to:
2. Write to the Timer High and Low Byte registers to set the starting count value (usually
3. Write to the Timer Reload High and Low Byte Registers to set the Reload value.
4. If desired, enable the timer interrupt and set the timer interrupt priority by writing to
5. If using the Timer Output function, configure the associated GPIO port pin for the
ONE-SHOT Mode Time-Out Period (s)
the relevant interrupt registers.
Timer Output alternate function.
0001H
Reload in CONTINUOUS mode, counting always begins at the reset value of
the relevant interrupt registers.
Timer Output alternate function.
Set the prescale value
If using the Timer Output alternate function, set the initial output level
(High or Low).
Disable the timer
Configure the timer for CONTINUOUS mode
Set the prescale value.
If using the Timer Output alternate function, set the initial output level
(High or Low).
). This only affects the first pass in CONTINUOUS mode. After the first timer
0001H
=
(
------------------------------------------------------------------------------------------------------ -
Reload Value Start Value
and counting resumes. Also, if the Timer
System Clock Frequency (Hz)
Z8 Encore! XP
Product Specification
®
)xPrescale
F0822 Series
0001H
Timers
.
71