EP3C16F484A7N Altera, EP3C16F484A7N Datasheet - Page 133

Cyclone III

EP3C16F484A7N

Manufacturer Part Number
EP3C16F484A7N
Description
Cyclone III
Manufacturer
Altera
Datasheet

Specifications of EP3C16F484A7N

Family Name
Cyclone III
Number Of Logic Blocks/elements
15408
# I/os (max)
346
Frequency (max)
437.5MHz
Process Technology
65nm
Operating Supply Voltage (typ)
1.2V
Logic Cells
15408
Ram Bits
516096
Operating Supply Voltage (min)
1.15V
Operating Supply Voltage (max)
1.25V
Operating Temp Range
-40C to 125C
Operating Temperature Classification
Automotive
Mounting
Surface Mount
Pin Count
484
Package Type
FBGA
Lead Free Status / Rohs Status
Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EP3C16F484A7N
Manufacturer:
ALTERA
Quantity:
717
Part Number:
EP3C16F484A7N
Manufacturer:
ALTERA
0
Part Number:
EP3C16F484A7N
Manufacturer:
ALTERA/阿尔特拉
Quantity:
20 000
Chapter 7: High-Speed Differential Interfaces in the Cyclone III Device Family
High-Speed I/O Standards Support
Figure 7–4. BLVDS Topology with Cyclone III Device Family Transmitters and Receivers
© December 2009
100 kΩ
100 kΩ
GND
f
f
R
1
T
Altera Corporation
V
CC
Figure 7–4
pairs.
The BLVDS I/O standard is supported on all I/O banks of the Cyclone III device
family. The BLVDS transmitter uses two single-ended output buffers with the second
output buffer programmed as inverted, while the BLVDS receiver uses a true LVDS
input buffer. The transmitter and receiver share the same pins. An output-enabled
(OE) signal is required to tristate the output buffers when the LVDS input buffer
receives a signal.
For more information about BLVDS I/O features and electrical specifications, refer to
the
Handbook and the
chapters.
For more information and design examples about implementing the BLVDS interfaces
in the Cyclone III device family, refer to
Cyclone III, Stratix III and Stratix IV
Designing with BLVDS
The BLVDS bidirectional communication requires termination at both ends of the bus
in BLVDS. The termination resistor (R
which in turn depends on the loading on the bus. Increasing the load decreases the
bus differential impedance. With termination at both ends of the bus, termination is
not required between the two signals at the input buffer. A single series resistor (R
required at the output buffer to match the output buffer impedance to the
transmission line impedance. However, this series resistor affects the voltage swing at
the input buffer. The maximum data rate achievable depends on many factors.
Altera recommends that you perform simulation using the IBIS model while
considering factors such as bus loading, termination values, and output and input
buffer location on the bus to ensure that the required performance is achieved.
50 Ω
50
Cyclone III Device I/O Features
Ω
Output
Data
shows a typical BLVDS topology with multiple transmitter and receiver
Input
Data
Cyclone III Device Data Sheet
50 Ω
50 Ω
Output
Data
chapter in volume 1 of the Cyclone III Device
Devices.
Input
Data
T
) must match the bus differential impedance,
AN 522: Implementing Bus LVDS Interface in
50 Ω
50 Ω
and
Output
Data
Cyclone III LS Device Data Sheet
Cyclone III Device Handbook, Volume 1
Input
Data
50 Ω
50 Ω
V
CC
100 kΩ
100 k
GND
R
T
Ω
S
) is
7–9