PEB3265 Infineon Technologies Corporation, PEB3265 Datasheet - Page 118

no-image

PEB3265

Manufacturer Part Number
PEB3265
Description
(PEB326x / PEB426x) Dual Channel Slicofi-2 / Slic Duslic
Manufacturer
Infineon Technologies Corporation
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PEB3265F
Manufacturer:
INFINEON
Quantity:
111
Part Number:
PEB3265F
Manufacturer:
D
Quantity:
44
Part Number:
PEB3265F V1.5
Manufacturer:
Infineon
Quantity:
853
Part Number:
PEB3265FV1.5
Manufacturer:
INFTEL
Quantity:
20 000
Part Number:
PEB3265H
Manufacturer:
Infineon
Quantity:
9
Part Number:
PEB3265H
Manufacturer:
SIEMENS
Quantity:
5 510
Part Number:
PEB3265H-V13
Manufacturer:
Infineon Technologies
Quantity:
10 000
Part Number:
PEB3265HV1.2
Manufacturer:
INFINEON/英飞凌
Quantity:
20 000
Part Number:
PEB3265HV1.3
Manufacturer:
INFINEON/英飞凌
Quantity:
20 000
Part Number:
PEB3265HV1.5
Quantity:
2 416
Part Number:
PEB3265HV1.5
Manufacturer:
INF
Quantity:
20 000
Preliminary
Table 33
LM-AC
0
1
:
6
7
The integration function accumulates and sums up the levelmeter values over a set time
period. The time period from 1*16 ms to 16*16 ms is set by the bits LM-ITIME[3:0] in
register LMCR3. The integration function can be turned on and off by bit LM-EN in
register LMCR1.
The number of samples N
N
The level can be calculated by:
The result registers get frequently updated after an integration period, if bit LM-EN in
register LMCR1 = 1. If the bit LM-ONCE in register LMCR1 is set to 1 then the integration
is executed only once. To start again bit LM-EN has to be set from 0 to 1.
The levelmeter result can be transferred to the PCM/IOM-2 interface, depending on bit
LM2PCM in register LMCR1.
Measurement of currents via ITAC
In order to do current measurements via pin ITAC, all feedback loops (IM-filters and TH-
filters) should be disabled. To simplify the formulas, the programmable receive and
transmit gain is disabled.
This is done by setting the following bits:
Register BCR4:
Register TSTR4:
Register LMCR1: TEST-EN = 1
Data Sheet
U dBm0
Samples
= LM-ITIME * 8000
=
20
K
K
1
½
:
1/64
1/128
INTAC
log
INTAC
æ
è
AR-DIS = 1, AX-DIS = 1, TH-DIS = 1,
IM-DIS = 1, FRR-DIS = 1, FRX-DIS = 1
OPIM-AN = 1, OPIM-4M = 1
LM Result
Setting Table
Samples
------------------------------------------------------------ -
2
for the integrator is defined by:
K INT
N Samples
118
ö
+
3.14
Operational Description
2000-07-14