PEB3265 Infineon Technologies Corporation, PEB3265 Datasheet - Page 193

no-image

PEB3265

Manufacturer Part Number
PEB3265
Description
(PEB326x / PEB426x) Dual Channel Slicofi-2 / Slic Duslic
Manufacturer
Infineon Technologies Corporation
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PEB3265F
Manufacturer:
INFINEON
Quantity:
111
Part Number:
PEB3265F
Manufacturer:
D
Quantity:
44
Part Number:
PEB3265F V1.5
Manufacturer:
Infineon
Quantity:
853
Part Number:
PEB3265FV1.5
Manufacturer:
INFTEL
Quantity:
20 000
Part Number:
PEB3265H
Manufacturer:
Infineon
Quantity:
9
Part Number:
PEB3265H
Manufacturer:
SIEMENS
Quantity:
5 510
Part Number:
PEB3265H-V13
Manufacturer:
Infineon Technologies
Quantity:
10 000
Part Number:
PEB3265HV1.2
Manufacturer:
INFINEON/英飞凌
Quantity:
20 000
Part Number:
PEB3265HV1.3
Manufacturer:
INFINEON/英飞凌
Quantity:
20 000
Part Number:
PEB3265HV1.5
Quantity:
2 416
Part Number:
PEB3265HV1.5
Manufacturer:
INF
Quantity:
20 000
Preliminary
AC-XGAIN Analog gain in transmit direction (should be set to zero).
UTDX-SRC
PDOT-DIS
Data Sheet
AC-XGAIN = 0
AC-XGAIN = 1
Power Down Overtemperature Disable
PDOT-DIS = 0
PDOT-DIS = 1
Universal Tone Detector transmit source
UTDX-SRC = 0
UTDX-SRC = 1
(see
Figure 32
No additional analog gain in transmit direction.
Additional 6 dB analog amplification in transmit
direction.
on
SLICOFI-2x Command Structure and Programming
When overtemperature is detected, the SLIC is
automatically switched into Power Down High
Impedance mode (PDH). This is the safe operation
mode for the SLIC-E/-E2/-P in case of
overtemperature. To leave the automatically
activated PDH mode, DuSLIC has to be switched
manually to PDH mode and then in the mode as
desired.
When over temperature is detected, the SLIC-E/-E2/
-P doesn’t automatically switch into Power Down
High Impedance mode. In this case the output
current of the SLIC-E/-E2/-P buffers is limited to a
value which keeps the SLIC-E/-E2/-P temperature
below the upper temperature limit.
from the transmit path directly (UTDX-SUM = 0) or
uses the data from the sum signal of receive path
and LEC (if LEC is enabled) (UTDX-SUM = 1).
from the LEC output, if the LEC is enabled (LEC-EN
= 1), otherwise the UTD unit uses automatically the
transmit signal.
The Universal Tone Detection unit uses the data
The Universal Tone Detection unit uses the data
Page