PEB3265 Infineon Technologies Corporation, PEB3265 Datasheet - Page 62

no-image

PEB3265

Manufacturer Part Number
PEB3265
Description
(PEB326x / PEB426x) Dual Channel Slicofi-2 / Slic Duslic
Manufacturer
Infineon Technologies Corporation
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PEB3265F
Manufacturer:
INFINEON
Quantity:
111
Part Number:
PEB3265F
Manufacturer:
D
Quantity:
44
Part Number:
PEB3265F V1.5
Manufacturer:
Infineon
Quantity:
853
Part Number:
PEB3265FV1.5
Manufacturer:
INFTEL
Quantity:
20 000
Part Number:
PEB3265H
Manufacturer:
Infineon
Quantity:
9
Part Number:
PEB3265H
Manufacturer:
SIEMENS
Quantity:
5 510
Part Number:
PEB3265H-V13
Manufacturer:
Infineon Technologies
Quantity:
10 000
Part Number:
PEB3265HV1.2
Manufacturer:
INFINEON/英飞凌
Quantity:
20 000
Part Number:
PEB3265HV1.3
Manufacturer:
INFINEON/英飞凌
Quantity:
20 000
Part Number:
PEB3265HV1.5
Quantity:
2 416
Part Number:
PEB3265HV1.5
Manufacturer:
INF
Quantity:
20 000
Preliminary
3.7.2
SLICOFI-2/-2S also supports metering by polarity reversal by changing the actual
polarity of the voltages on the TIP/RING lines. Polarity reversal is activated by switching
the REVPOL bit in register BCR1 to one or switching to the “Active with Metering” mode
by the CIDD or CIOP command (see
Page
3.7.2.1
Some applications require a smooth polarity reversal (soft reversal), as shown in
Figure
reversal is deactivated by the SOFT-DIS bit in register BCR2.
Figure 30
START: The soft ramp starts by setting the REVPOL bit in register BCR1 to 1. The DC
characteristic is switched off.
SR-END1: At the soft reversal end one point, the DC characteristic is switched on again.
Programmable by the DuSLICOS software, e.g. U/8.
SR-END2: At the soft reversal end two point, the soft ramp is switched off.
Programmable by the DuSLICOS software, e.g. 1/16
From START to SR-END2 the READY bit in register INTREG2 is set to 0 (see register
description in
Data Sheet
SOFT-DIS = 1
SOFT-DIS = 0
78).
30. Soft reversal helps to prevent negative effects like non-required ringing. Soft
Metering by Polarity Reversal
Soft Reversal
Chapter 6.3.1.2
Soft Reversal (Example for Open Loop)
Immediate reversal is performed (hard reversal)
Soft reversal is performed. Transition time (time from START to SR-
END1, see
default value 80 ms.
V
TIP/RING
-10
-15
-20
-25
2 5
2 0
1 5
1 0
-5
5
0
0
[V]
U
START
5 0
Figure
for further information).
U/8
“Operating Modes for the DuSLIC Chip Set” on
1 00
30) is programmable by CRAM coefficients,
SR-END1
62
150
2 00
SR-END1.
SR-END2
= 1/16*SR-END1
250
Functional Description
t [ms]
ezm14038.wmf
2000-07-14
DuSLIC