PEB3265 Infineon Technologies Corporation, PEB3265 Datasheet - Page 312

no-image

PEB3265

Manufacturer Part Number
PEB3265
Description
(PEB326x / PEB426x) Dual Channel Slicofi-2 / Slic Duslic
Manufacturer
Infineon Technologies Corporation
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PEB3265F
Manufacturer:
INFINEON
Quantity:
111
Part Number:
PEB3265F
Manufacturer:
D
Quantity:
44
Part Number:
PEB3265F V1.5
Manufacturer:
Infineon
Quantity:
853
Part Number:
PEB3265FV1.5
Manufacturer:
INFTEL
Quantity:
20 000
Part Number:
PEB3265H
Manufacturer:
Infineon
Quantity:
9
Part Number:
PEB3265H
Manufacturer:
SIEMENS
Quantity:
5 510
Part Number:
PEB3265H-V13
Manufacturer:
Infineon Technologies
Quantity:
10 000
Part Number:
PEB3265HV1.2
Manufacturer:
INFINEON/英飞凌
Quantity:
20 000
Part Number:
PEB3265HV1.3
Manufacturer:
INFINEON/英飞凌
Quantity:
20 000
Part Number:
PEB3265HV1.5
Quantity:
2 416
Part Number:
PEB3265HV1.5
Manufacturer:
INF
Quantity:
20 000
Preliminary
6.3.3
The Command/Indication (C/I) channel is used to communicate real time status
information and for fast controlling of the DuSLIC. Data on the C/I channel are
continuously transmitted in each frame until new data are sent.
Data Downstream C/I – Channel Byte (Receive) – IOM-CIDD
The first six CIDD data bits control the general operating modes for both DuSLIC
channels. According to the IOM-2 specification, new data have to be present for at least
two frames to be accepted.
Table 70
CIDD
M2
1
0
0
1
1
1
0
Bit
)
M2A, M1A, M0A
M2B, M1B, M0B
MR, MX
Data Sheet
CIDD
IOM-2 Interface Command/Indication Byte
M1
1
0
1
0
1
0
0
M2A
7
M2, M1, M0: General Operating Mode
M1A
Select operating mode for DuSLIC channel A
Select operating mode for DuSLIC channel B
Handshake bits Monitor Receive and Transmit
(see
Page
M0
1
0
0
1
0
0
1
Data Downstream C/I – Channel Byte
6
“IOM-2 Interface Monitor Transfer Protocol” on
148)
M0A
SLICOFI-2x Command Structure and Programming
SLICOFI-2S/-2S2 Operating Mode
(for details see
Chip Set” on Page
Sleep, Power Down (PDRx)
Power Down High Impedance (PDH)
Any Active mode
Ringing (ACTR Burst On)
Active with Metering
Ground Start
Ring Pause
5
M2B
312
4
“Operating Modes for the DuSLIC
M1B
3
78)
M0B
2
DuSLIC-S/-S2
MR
1
2000-07-14
MX
0
N