PEB3265 Infineon Technologies Corporation, PEB3265 Datasheet - Page 177

no-image

PEB3265

Manufacturer Part Number
PEB3265
Description
(PEB326x / PEB426x) Dual Channel Slicofi-2 / Slic Duslic
Manufacturer
Infineon Technologies Corporation
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PEB3265F
Manufacturer:
INFINEON
Quantity:
111
Part Number:
PEB3265F
Manufacturer:
D
Quantity:
44
Part Number:
PEB3265F V1.5
Manufacturer:
Infineon
Quantity:
853
Part Number:
PEB3265FV1.5
Manufacturer:
INFTEL
Quantity:
20 000
Part Number:
PEB3265H
Manufacturer:
Infineon
Quantity:
9
Part Number:
PEB3265H
Manufacturer:
SIEMENS
Quantity:
5 510
Part Number:
PEB3265H-V13
Manufacturer:
Infineon Technologies
Quantity:
10 000
Part Number:
PEB3265HV1.2
Manufacturer:
INFINEON/英飞凌
Quantity:
20 000
Part Number:
PEB3265HV1.3
Manufacturer:
INFINEON/英飞凌
Quantity:
20 000
Part Number:
PEB3265HV1.5
Quantity:
2 416
Part Number:
PEB3265HV1.5
Manufacturer:
INF
Quantity:
20 000
Preliminary
Bit
After a hardware reset the RSTAT bit is set and generates an interrupt. Therefore the
default value of INTREG2 is 20h. After reading all four interrupt registers, the INTREG2
value changes to 4Fh.
LM-THRES
READY
RSTAT
LM-OK
IO[4:1]-DU
Data Sheet
08
H
INTREG2
THRES
LM-
7
Data on IO pins 1 to 4 filtered by DUP-IO counter and interrupt generation
masked by the IO[4:1]-DU-M bits. A change of any of this bits generates
an interrupt.
Reset status since last interrupt.
RSTAT = 0
RSTAT = 1
Level metering sequence has finished. An interrupt is only generated if
the LM-OK bit changes from 0 to 1.
LM-OK = 0
LM-OK = 1
Indication whether the level metering result is above or below the
threshold set by the CRAM coefficients
LM-THRES = 0 Level metering result is below threshold.
LM-THRES = 1 Level metering result is above threshold.
Indication whether the ramp generator has finished. An interrupt is only
generated if the READY bit changes from 0 to 1. Upon a new start of the
ramp generator, the bit is set to 0. For further information regarding soft
reversal see
READY = 0
READY = 1
READY RSTAT
6
Interrupt Register 2 (read-only)
Chapter
Ramp generator active.
Ramp generator not active.
No reset has occurred since the last interrupt.
Reset has occurred since the last interrupt.
Level metering result not ready.
Level metering result ready.
5
SLICOFI-2x Command Structure and Programming
3.7.2.1.
LM-OK
4
177
3
2
IO[4:1]-DU
20
DuSLIC-E/-E2/-P
H
1
2000-07-14
0
Y

Related parts for PEB3265