PEB3265 Infineon Technologies Corporation, PEB3265 Datasheet - Page 161

no-image

PEB3265

Manufacturer Part Number
PEB3265
Description
(PEB326x / PEB426x) Dual Channel Slicofi-2 / Slic Duslic
Manufacturer
Infineon Technologies Corporation
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PEB3265F
Manufacturer:
INFINEON
Quantity:
111
Part Number:
PEB3265F
Manufacturer:
D
Quantity:
44
Part Number:
PEB3265F V1.5
Manufacturer:
Infineon
Quantity:
853
Part Number:
PEB3265FV1.5
Manufacturer:
INFTEL
Quantity:
20 000
Part Number:
PEB3265H
Manufacturer:
Infineon
Quantity:
9
Part Number:
PEB3265H
Manufacturer:
SIEMENS
Quantity:
5 510
Part Number:
PEB3265H-V13
Manufacturer:
Infineon Technologies
Quantity:
10 000
Part Number:
PEB3265HV1.2
Manufacturer:
INFINEON/英飞凌
Quantity:
20 000
Part Number:
PEB3265HV1.3
Manufacturer:
INFINEON/英飞凌
Quantity:
20 000
Part Number:
PEB3265HV1.5
Quantity:
2 416
Part Number:
PEB3265HV1.5
Manufacturer:
INF
Quantity:
20 000
DuSLIC
Interfaces
Preliminary
Active (ACTL, ACTH, ACTR): These are the regular transmit and receive modes for
voice band. The line driving section is operated between
V
,
V
,
V
and
BATL
BATH
BATR
V
.
BGND
V
PDRR is a power down mode providing a connection of 5 k
each from TIP to
BGND
V
and RING to
, respectively, while the outputs of the buffers show high impedance.
BATR
The current through these resistors is sensed and transferred to the IT pin to allow off-
hook supervision.
PDRRL is used as a transition mode at a mode change from PDRR mode to ACTR mode
(automatically initiated by SLICOFI-2 at a mode change from PDRR to ACTR).
High Impedance (HIR/HIT): In this mode each of the line outputs can be programmed
to show high impedance. HIT switches off the TIP buffer, while the current through the
RING output still can be measured by IT or IL. Programming HIR switches off the RING
buffer.
For Both Operating Modes of SLIC-P (Ringing and Non Ringing):
The Power Down modes are intended to reduce the power consumption of the linecard
to a minimum: the PEB 4266 is switched off completely, no operation is available.
With respect to the output impedance of TIP and RING, the following Power Down
modes have to be distinguished:
The PDH mode offers high impedance at TIP and RING.
High Impedance (HIRT): The output buffers of the Tip and Ring line show high
impedance.
Data Sheet
161
2000-07-14

Related parts for PEB3265