S9S12G128F0VLL Freescale Semiconductor, S9S12G128F0VLL Datasheet - Page 860

no-image

S9S12G128F0VLL

Manufacturer Part Number
S9S12G128F0VLL
Description
16-bit Microcontrollers - MCU 16BIT 128K FLASH
Manufacturer
Freescale Semiconductor
Datasheet

Specifications of S9S12G128F0VLL

Rohs
yes
Core
S12
Processor Series
MC9S12G
Data Bus Width
16 bit
Maximum Clock Frequency
1 MHz
Program Memory Size
128 KB
Data Ram Size
8 KB
On-chip Adc
Yes
Operating Supply Voltage
3.13 V to 5.5 V
Operating Temperature Range
- 40 C to + 125 C
Package / Case
LQFP-100
Mounting Style
SMD/SMT
A/d Bit Size
10 bit, 12 bit
A/d Channels Available
12
Interface Type
SPI
Maximum Operating Temperature
+ 125 C
Minimum Operating Temperature
- 40 C
Number Of Programmable I/os
86
Number Of Timers
8
Program Memory Type
Flash
Supply Voltage - Max
5.5 V
Supply Voltage - Min
3.13 V

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
S9S12G128F0VLL
Manufacturer:
FREESCALE
Quantity:
2 250
Part Number:
S9S12G128F0VLL
Manufacturer:
FREESCALE
Quantity:
2 250
Part Number:
S9S12G128F0VLLR
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
32 KByte Flash Module (S12FTMRG32K1V1)
Upon clearing CCIF to launch the Erase Verify P-Flash Section command, the Memory Controller will
verify the selected section of Flash memory is erased. The CCIF flag will set after the Erase Verify P-Flash
Section operation has completed. If the section is not erased, it means blank check failed, both MGSTAT
bits will be set.
25.4.6.4
The Read Once command provides read access to a reserved 64 byte field (8 phrases) located in the
nonvolatile information register of P-Flash. The Read Once field is programmed using the Program Once
command described in
block containing the Program Once reserved field to avoid code runaway.
862
Register
FSTAT
Read Once Command
Table 25-36. Erase Verify P-Flash Section Command FCCOB Requirements
Table 25-37. Erase Verify P-Flash Section Command Error Handling
CCOBIX[2:0]
MGSTAT1
MGSTAT0
ACCERR
Error Bit
FPVIOL
Section
Table 25-38. Read Once Command FCCOB Requirements
CCOBIX[2:0]
000
001
010
011
100
101
000
001
010
25.4.6.6. The Read Once command must not be executed from the Flash
MC9S12G Family Reference Manual,
Set if CCOBIX[2:0] != 010 at command launch
Set if command not available in current mode (see
Set if an invalid global address [17:0] is supplied see
Set if a misaligned phrase address is supplied (global address [2:0] != 000)
Set if the requested section crosses a the P-Flash address boundary
None
Set if any errors have been encountered during the read or if blank check failed.
Set if any non-correctable errors have been encountered during the read or if
blank check failed.
Global address [15:0] of the first phrase to be verified
Read Once phrase index (0x0000 - 0x0007)
0x04
Number of phrases to be verified
0x03
Read Once word 0 value
Read Once word 1 value
Read Once word 2 value
Read Once word 3 value
FCCOB Parameters
FCCOB Parameters
Global address [17:16] of
Error Condition
a P-Flash block
Rev.1.23
Not Required
Table
Table
25-27)
25-3)
Freescale Semiconductor

Related parts for S9S12G128F0VLL