AT91SAM7S128C-MU Atmel, AT91SAM7S128C-MU Datasheet - Page 733

IC MCU ARM7 128K FLASH 64-QFN

AT91SAM7S128C-MU

Manufacturer Part Number
AT91SAM7S128C-MU
Description
IC MCU ARM7 128K FLASH 64-QFN
Manufacturer
Atmel
Series
AT91SAMr
Datasheets

Specifications of AT91SAM7S128C-MU

Core Processor
ARM7
Core Size
16/32-Bit
Speed
55MHz
Connectivity
I²C, SPI, SSC, UART/USART, USB
Peripherals
Brown-out Detect/Reset, DMA, POR, PWM, WDT
Number Of I /o
32
Program Memory Size
128KB (128K x 8)
Program Memory Type
FLASH
Ram Size
32K x 8
Voltage - Supply (vcc/vdd)
1.65 V ~ 1.95 V
Data Converters
A/D 8x10b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
64-VQFN Exposed Pad, 64-HVQFN, 64-SQFN, 64-DHVQFN
Core
ARM7TDMI
For Use With
AT91SAM-ICE - EMULATOR FOR AT91 ARM7/ARM9AT91SAM7S-EK - KIT EVAL FOR ARM AT91SAM7S
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
Lead Free Status / Rohs Status
 Details
Other names
AT91SAM7S128-MU
AT91SAM7S128-MU

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AT91SAM7S128C-MU
Manufacturer:
ATMEL
Quantity:
670
40.20.6.6
40.20.6.7
40.20.6.8
40.20.6.9
40.20.6.10
40.20.6.11
6175K–ATARM–30-Aug-10
SPI: Baudrate Set to 1
SPI: Disable In Slave Mode
SPI: Disable Issue
SPI: Software Reset and SPIEN Bit
SPI: CSAAT = 1 and Delay
SPI: Bad Serial Clock Generation on 2nd Chip Select
When Baudrate is set at 1 (i.e. when serial clock frequency equals the system clock frequency)
and when the BITS field of the SPI_CSR register (number of bits to be transmitted) equals an
ODD value (in this case 9,11,13 or 15), an additional pulse will be generated on output SPCK.
Everything is OK if the BITS field equals 8,10,12,14 or 16 and Baudrate = 1.
None.
The SPI disable is not possible in slave mode.
Read first the received data, then perform the software reset.
The SPI Command “SPI Disable” is not possible during a transfer, it must be performed only
after TX_EMPTY rising else there is everlasting dummy transfers occur.
None.
The SPI Command “software reset” does not reset the SPIEN config bit. Therefore rewriting an
SPI enable command does not set TX_READY, TX_EMPTY flags.
Send SPI disable command after a software reset.
If CSAAT = 1 for current access and there is no more TX request for a time greater
than DLYBCT + DLYBCS, then if an access is requested on another slave, the NPCS bus
switches from one CS to the one requested without DLYBCS. External Slaves may reach a con-
tention on SPI_MISO line for a short period.
Assert the Last Transfer Command (NPCS de-activation) for the last character of each slave.
Bad Serial clock generation on the 2nd chip select when SCBR = 1, CPOL = 1 and NCPHA = 0.
This occurs using SPI with the following conditions:
• Master Mode
• CPOL = 1 and NCPHA = 0
• Multiple chip selects are used with one transfer with Baud rate (SCBR) equal to 1 (i.e., when
• Transmitting with the slowest chip select and then with the fastest one, then an additional
serial clock frequency equals the system clock frequency) and the other transfers set with
SCBR are not equal to 1
pulse is generated on output SPCK during the second transfer.
Problem Fix/Workaround
Problem Fix/Workaround
Problem Fix/Workaround
Problem Fix/Workaround
Problem Fix/Workaround
AT91SAM7S Series Preliminary
733