C500DA101 Omron, C500DA101 Datasheet - Page 109

no-image

C500DA101

Manufacturer Part Number
C500DA101
Description
ANALOG OUTPUT UNIT
Manufacturer
Omron
Datasheet

Specifications of C500DA101

Leaded Process Compatible
No
Peak Reflow Compatible (260 C)
No
No. Of Analog Outputs
4
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
5-7
5-7-1 Basic Programming
READ/WRIT Execution Restrictions
5-7-2
94
User Programming Examples
User Programming Examples
Using the Unit Configuration Worksheet
1, 2, 3...
1, 2, 3...
Note When configuring the Unit’s advanced functions, use the following steps.
This section provides some user programming examples for CV-series PCs.
These examples may need to be altered for use with other PCs. Refer to the doc-
umentation on programming for your PC for details.
The ladder diagram instruction shown below is used in conjunction with the de-
fault settings. It can be executed to read the A/D data and alarm flags for each
input point into the data memory (DM) area. This programming rung assumes
that the Unit is in its factory default settings.
Alarm flags and analog conversion data will be stored in CPU Unit memory be-
ginning at the DM address specified in the ladder diagram instruction.
Appendix A is a worksheet to use when configuring the advanced functions
available in the Unit. It is particularly useful in setting up a table in the CPU Unit
data memory area that corresponds to the Unit memory map. The data can then
be easily transferred to the Unit using the I/O WRITE ladder instruction.
DM xxxx
DM xxxx + 1 to xxxx + 16
1. The differentiated READ and WRIT instructions cannot be executed for
2. The READ and WRIT instructions cannot be simultaneously executed for
3. One SYSMAC BUS/2 Remote I/O Master Unit can simultaneously handle
4. Therefore, when continuously executing READ instructions, you can use
5. Up to four SYSMAC BUS/2 Remote I/O Master Units can be mounted to the
6. Up to 255 words can be transferred using a READ or WRIT instruction.
1. Disable the input point to be configured in Unit memory map word 47.
2. Reconfigure the input point for the desired advanced function.
3. Enable the input point in Unit memory map word 47.
Special I/O Units on SYSMAC BUS/2 Slave Racks. The READ and WRIT
instructions must be executed until the Equals Flag (A50006) turns ON indi-
cating that the execution is completed.
the same Special I/O Unit. In such cases, execute WRIT first, and after the
execution is completed, execute READ.
up to two READ and WRIT instructions. If two READ and WRIT instructions
are executed for Units mounted to SYSMAC BUS/2 Slave Racks and an at-
tempt is made to execute a READ or WRIT instruction for a third Unit, the
Carry Flag (A50004) will be turned ON without executing the third instruc-
tion.
the READ and WRIT instructions for a maximum of two Special I/O Units
under each SYSMAC BUS/2 Remote I/O Master Unit.
CV1000 or CV2000. In this case, therefore, up to eight READ and WRIT in-
structions can be executed simultaneously.
Always ON
A 50013
[READ
Unit alarm flags
Input conversion data in
BCD format, for inputs 1 to
16
N: Read 17 locations
S: Unit I/O word
D: Start word to store data in DM
N=17
S=yyyy
D=xxxx]
Section
5-7

Related parts for C500DA101