C500DA101 Omron, C500DA101 Datasheet - Page 182

no-image

C500DA101

Manufacturer Part Number
C500DA101
Description
ANALOG OUTPUT UNIT
Manufacturer
Omron
Datasheet

Specifications of C500DA101

Leaded Process Compatible
No
Peak Reflow Compatible (260 C)
No
No. Of Analog Outputs
4
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Data Exchange with CPU Unit
Words
33
34
35
36
37
38
39
40
0 to 15 1
0 to 15 2
0 to 15 3
0 to 15 4
0 to 15 5
0 to 15 6
0 to 15 7
0 to 15 8
Bits
Output
points
Output Ramp
Set Time for
Output Point 1
Output Ramp
Set Time for
Output Point 2
Output Ramp
Set Time for
Output Point 3
Output Ramp
Set Time for
Output Point 4
Output Ramp
Set Time for
Output Point 5
Output Ramp
Set Time for
Output Point 6
Output Ramp
Set Time for
Output Point 7
Output Ramp
Set Time for
Output Point 8
Name
Output ramp set time for output
point 1 (in ms). It must be 8 ms
or more.
Output ramp set time for output
point 2 (in ms). It must be 8 ms
or more.
Output ramp set time for output
point 3 (in ms). It must be 8 ms
or more.
Output ramp set time for output
point 4 (in ms). It must be 8 ms
or more.
Output ramp set time for output
point 5 (in ms). It must be 8 ms
or more.
Output ramp set time for output
point 6 (in ms). It must be 8 ms
or more.
Output ramp set time for output
point 7 (in ms). It must be 8 ms
or more.
Output ramp set time for output
point 8 (in ms). It must be 8 ms
or more.
Description
BCD:
8 to 7999 (0008 to
7999
Binary:
8 to 32767 (0008
to 7FFF
to 7FFF
Hex
Hex
Data
Hex
Hex
)
)
)
)
0008
Default
Section
Hex
Write: W
R/W
Read: R
171
9-3