C500DA101 Omron, C500DA101 Datasheet - Page 61

no-image

C500DA101

Manufacturer Part Number
C500DA101
Description
ANALOG OUTPUT UNIT
Manufacturer
Omron
Datasheet

Specifications of C500DA101

Leaded Process Compatible
No
Peak Reflow Compatible (260 C)
No
No. Of Analog Outputs
4
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Two-word Operation
Ladder Programming Example Using C1000H
(Continued on next page.)
First Scan Flag
First Scan Flag
25315
25315
07000
25506
(EQ)
MOV(21)
MOV(21)
MOV(21)
MOV(21)
MOV(21)
MOV(21)
MOV(21)
MOV(21)
MOV(21)
MOV(21)
WRIT(87)
DM0000
DM0001
DM0002
DM0003
DM0004
DM0005
DM0006
DM0007
DM0008
DM0009
DM0000
07000
#F0FF
#C000
#0005
#0010
#0020
#0050
#0000
#3000
#1000
#5000
#0010
000
Specifies the points to
be used and mean val-
ue settings.
Specifies scaling set-
tings.
Input point 5
(5 samples)
Input point 6
(10 samples)
Input point 7
(20 samples)
Input point 8
(50 samples)
Input point 7
offset data
Input point 7
gain data
Input point 8
offset data
Input point 8
gain data
Transfers the 10 words of parameters from
DM 0000 through DM 0009 to the Analog
Input Unit.
When the transfer is complete, SR
25506 (the Equal Flags) turns ON.
Here, IR 07000 is used as a work bit to
hold the status of EQ at this point.
Sets the
mean
data
(sampling
counts).
Sets the
scaling
data.
These settings
can be made via
the Programming
Console using
data modification
functions instead
of in program-
ming, if desired.
Section 4-3
45