C500DA101 Omron, C500DA101 Datasheet - Page 179

no-image

C500DA101

Manufacturer Part Number
C500DA101
Description
ANALOG OUTPUT UNIT
Manufacturer
Omron
Datasheet

Specifications of C500DA101

Leaded Process Compatible
No
Peak Reflow Compatible (260 C)
No
No. Of Analog Outputs
4
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Memory Map Contents
168
Data Exchange with CPU Unit
Words
00
01 to
08
09
10
11
0 to 7
8 to 15 1 to 8
0 to 15 1 to 8
0 to 7
8 to 15 1 to 8
0 to 7
8 to 15 1 to 8
0 to 7
Bits
1 to 8
1 to 8
1 to 8
1 to 8
Output
points
Invalid Data
Received Flags
Conversion
Error Flags
Conversion
Data
Scaling
Enabled Flags
Output Ramp
Enabled Flags
Upper/Lower
Limit Enabled
Flags
BCD/Binary
Mode Selection
Flags
Conversion
Data Enabled
Flags
Name
Turned ON by the Analog
Output Unit when invalid data
is written to an output point in
RAM. Turned OFF when valid
data is written to the same part
of RAM.
When this error occurs, bit 3 of
word n+1 (bit 3 of word n+3) in
the allocated I/O words is also
turned ON.
Turned ON when a conversion
error is detected in the Analog
Output Unit.
When this error occurs, bit 4 of
word n+1 (bit 4 of word n+3) in
the allocated I/O words is also
turned ON.
Conversion source data for
each output signal.
conversion data can be in
either BCD or binary (set in
bits 8 to 15 of address 14 in
RAM).
If the scaling function is
disabled, conversion data is
taken immediately before
conversion. If the scaling
function is enabled, conversion
data is in engineering units.
(This data is scaled and then
subject to conversion.)
If the upper/lower limit function
is enabled, the upper and
lower limits are written
whenever values above the
upper limit or below the lower
limit are set.
Turned ON by the Analog
Output Unit to indicate status
of scaling specified in bits 00 to
07 of word 13.
Turned ON by the Analog
Output Unit to indicate status
of the output ramps specified
in bits 08 to 15 of word 13.
Turned ON by the Analog
Output Unit to indicate status
of the upper/lower limit function
specified in bits 00 to 07 of
word 14.
Turned ON by the Analog
Output Unit to indicate
selection of either the BCD or
binary mode specified in bits
08 to 15 of word 14.
Turned ON by the Analog
Output Unit to indicate the
output points specified in bits
00 to 07 of word 15.
Description
ON: Error
OFF: Normal
ON: Error
OFF: Normal
With No Scaling
BCD:
0 to 4095
(0000 to 4095
or
–2048 to 2048
(A048 to 2048
Binary:
0000 to 0FFF
or
F800 to 07FF
With Scaling
BCD:
–7999 to 7999
(F999 to 7999
Binary:
–32767 to 32767
(8001 to 7FFF
ON: Enabled
OFF: Disabled
ON: Enabled
OFF: Disabled
ON: Enabled
OFF: Disabled
ON: BCD
OFF: Binary
ON: Enabled
OFF: Disabled
Data
Hex
Hex
Hex
Hex
Hex
Hex
)
)
)
)
0
0
0000
0
0
0
1
0
Default
Section
Hex
Write: W
R
R
R/W
R
R
R
R
R
Read: R
9-3