C500DA101 Omron, C500DA101 Datasheet - Page 216
C500DA101
Manufacturer Part Number
C500DA101
Description
ANALOG OUTPUT UNIT
Manufacturer
Omron
Datasheet
1.C500AD101.pdf
(226 pages)
Specifications of C500DA101
Leaded Process Compatible
No
Peak Reflow Compatible (260 C)
No
No. Of Analog Outputs
4
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
- Current page: 216 of 226
- Download datasheet (2Mb)
DM Memory Coding Sheets
49
50
51
52
53
54
55
56
Word
0 to 15 5
0 to 15
0 to 15 6
0 to 15
0 to 15 7
0 to 15
0 to 15 8
0 to 15
Bit
Output
point
Value
Output Lower
Limit (Output
Point 5)
Output Upper
Limit (Output
Point 5)
Output Lower
Limit (Output
Point 6)
Output Upper
Limit (Output
Point 6)
Output Lower
Limit (Output
Point 7)
Output Upper
Limit (Output
Point 7)
Output Lower
Limit (Output
Point 8)
Output Upper
Limit (Output
Point 8)
Name
Output lower limit for output
point 5. This is used to restrict
the output signal range. When
the scaling function is enabled,
data is set in engineering units.
Output upper limit for output
point 5. This is used to restrict
the output signal range. When
the scaling function is enabled,
data is set in engineering units.
Output lower limit for output
point 6. This is used to restrict
the output signal range. When
the scaling function is enabled,
data is set in engineering units.
Output upper limit for output
point 6. This is used to restrict
the output signal range. When
the scaling function is enabled,
data is set in engineering units.
Output lower limit for output
point 7. This is used to restrict
the output signal range. When
the scaling function is enabled,
data is set in engineering units.
Output upper limit for output
point 7. This is used to restrict
the output signal range. When
the scaling function is enabled,
data is set in engineering units.
Output lower limit for output
point 8. This is used to restrict
the output signal range. When
the scaling function is enabled,
data is set in engineering units.
Output upper limit for output
point 8. This is used to restrict
the output signal range. When
the scaling function is enabled,
data is set in engineering units.
Description
With No Scaling
BCD:
0 to 4095
(0000 to 4095
or
or
–2048 to 2048
(A048 to 2048
Binary:
0000 to 0FFF
or
or
F800 to 07FF
With Scaling
BCD:
–7999 to 7999
(F999 t 7999
(F999 to 7999
Binary:
–32767 to 32767
(8001 to 7FFF
Data
Hex
Hex
Hex
Appendix A
Hex
Hex
Hex
)
)
)
)
)
Lower
limit:
0000
Upper
limit:
limit:
4095
Default
Hex
Hex
205
Related parts for C500DA101
Image
Part Number
Description
Manufacturer
Datasheet
Request
R
Part Number:
Description:
G6S-2GLow Signal Relay
Manufacturer:
Omron Corporation
Datasheet:
Part Number:
Description:
Compact, Low-cost, SSR Switching 5 to 20 A
Manufacturer:
Omron Corporation
Datasheet:
Part Number:
Description:
Manufacturer:
Omron Corporation
Datasheet:
Part Number:
Description:
Manufacturer:
Omron Corporation
Datasheet:
Part Number:
Description:
Manufacturer:
Omron Corporation
Datasheet:
Part Number:
Description:
Manufacturer:
Omron Corporation
Datasheet:
Part Number:
Description:
Manufacturer:
Omron Corporation
Datasheet:
Part Number:
Description:
Manufacturer:
Omron Corporation
Datasheet: