IDT82V2108PX IDT, Integrated Device Technology Inc, IDT82V2108PX Datasheet - Page 219

no-image

IDT82V2108PX

Manufacturer Part Number
IDT82V2108PX
Description
IC FRAMER T1/J1/E1 8CH 128-PQFP
Manufacturer
IDT, Integrated Device Technology Inc
Datasheet

Specifications of IDT82V2108PX

Controller Type
T1/E1/J1 Framer
Interface
Parallel
Voltage - Supply
2.97 V ~ 3.63 V
Current - Supply
160mA
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
128-MQFP, 128-PQFP
Screening Level
Industrial
Mounting
Surface Mount
Operating Temperature (min)
-40C
Operating Temperature (max)
85C
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Other names
82V2108PX

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
IDT82V2108PX
Manufacturer:
IDT
Quantity:
191
Part Number:
IDT82V2108PX8
Manufacturer:
IDT, Integrated Device Technology Inc
Quantity:
10 000
Part Number:
IDT82V2108PXG
Manufacturer:
IDT, Integrated Device Technology Inc
Quantity:
10 000
Part Number:
IDT82V2108PXG
Manufacturer:
IDT
Quantity:
20 000
Company:
Part Number:
IDT82V2108PXG
Quantity:
604
Part Number:
IDT82V2108PXG8
Manufacturer:
IDT, Integrated Device Technology Inc
Quantity:
10 000
IDT82V2108
RSFSP, ALTIFP:
selected first framer.
IMTKC:
RPLC Signaling Trunk Conditioning Registers. This bit affects the corresponding time slot of MRSD and MRSSIG even if the multiplexed backplane is
enabled.
load Control Byte registers in the RPLC.
RSSIGn of all time slots is replaced with the data contained in the Signaling Trunk Conditioning registers. To enable this function, the PCCE (b0, T1/
J1-050H) of the RPLC must be set to logic 1.
Programming Information
In Receive Multiplexed mode, regardless of the setting in the RSFSP and the ALTRSFS, MRSFS can only indicate each F-bit of SF/ESF of the
This bit decides how to substitute the received data stream on RSDn and RSSIGn with contents in RPLC Data Trunk Conditioning Registers and
= 0: The data and signaling signals are substituted on a per-timeslot basis in accordance with the control bits contained in the per-timeslot Pay-
= 1: The data on RSDn of all time slots is replaced with the data contained in the Data Trunk Conditioning registers in RPLC, and the data on
RSFSP
0
0
1
1
ALTIFP
0
1
0
1
RSFSn asserts on each F-bit.
RSFSn asserts on every second F-bit (i.e., the F-bit of even frame if there is no channel offset).
RSFSn asserts on the first F-bit of every 12 frames (in SF format) or every 24 frames (in ESF format).
-
209
RSFSn Indication
T1 / E1 / J1 OCTAL FRAMER
March 5, 2009