TFRA08C13 OCTAL T1/E1 Framer
Facility Data Link
Receive HDLC Mode
This is the default mode of the FDL. The receive FDL receives serial data from the receive framer, identifies HDLC
frames, reconstructs data bytes, provides bit destuffing as necessary, and loads parallel data in the receive FIFO.
The receive queue manager forms a status of frame (SF) byte for each HDLC frame and stores the SF byte in the
receive FDL FIFO (register FDL_SR4) after the last data byte of the associated frame. HDLC frames consisting of
n bytes will have n + 1 bytes stored in the receive FIFO. The frame check sequence bytes (CRC) of the received
HDLC frame are not stored in the receive FIFO. When receiving ANSI PRM frames, the frame check sequence
bytes are stored in the receive FIFO.
The SF byte has the following format.
Table 42. Receive Status of Frame Byte
Bit 7 of the SF status byte is the CRC status bit. A 1 indicates that an incorrect CRC was detected. A 0 indicates
the CRC is correct. Bit 6 of the SF status byte is the abort status. A 1 indicates the frame associated with this status
byte was aborted (i.e., the abort sequence was detected after an opening flag and before a subsequent closing
flag). An abort can also cause bits 7 and/or 4 to be set to 1. An abort is not reported when a flag is followed by
seven ones. Bit 5 is the FIFO overrun bit. A 1 indicates that a receive FIFO overrun occurred (the 64-byte FIFO size
was exceeded). Bit 4 is the FIFO bad byte count that indicates whether or not the bit count received was a multiple
of eight (i.e., an integer number of bytes). A 1 indicates that the bit count received after 0-bit deletion was not a mul-
tiple of eight, and a 0 indicates that the bit count was a multiple of eight. When a non-byte-aligned frame is
received, all bits received are present in the receive FIFO. The byte before the SF status byte contains less than
eight valid data bits. The HDLC block provides no indication of how many of the bits in the byte are valid. User
application programming controls processing of non-byte-aligned frames. Bit 3—bit 0 of the SF status byte are not
used and are set to 0. A good frame is implied when the SF status byte is 00 (hex).
Receive FDL FIFO
Whenever an SF byte is present in the receive FIFO, the end of frame registers FDL_SR0 bit 4 (FREOF) and
FDL_SR2 bit 7 (FEOF) bits are set. The receiver queue status (register FDL_SR2 bit 0—bit 6) bits report the num-
ber of bytes up to and including the first SF byte. If no SF byte is present in the receive FIFO, the count directly
reflects the number of data bytes available to be read. Depending on the FDL frame size, it is possible for multiple
frames to be present in the receive FIFO. The receive fill level indicator register FDL_PR6 bit 0—bit 5 (FRIL) can be
programmed to tailor the service time interval to the system. The receive FIFO full register FDL_SR0 bit 3 (FRF)
interrupt is set in the interrupt status register when the receive FIFO reaches the preprogrammed full position. An
FREOF interrupt is also issued when the receiver has identified the end of frame and has written the SF byte for
that frame. An FDL overrun interrupt register FDL_SR0 bit 5 (FROVERUN) is generated when the receiver needs
to write either status or data to the receive FIFO while the receive FIFO is full. An overrun condition will cause the
last byte of the receive FIFO to be overwritten with an SF byte indicating the overrun status. A receive idle register
FDL_SR0 bit 6 (FRIDL) interrupt is issued whenever 15 or more continuous ones have been detected.
88
BAD CRC
RSF B7
RSF B6
ABORT
(continued)
OVERRUN
RSF B5
RFIFO
BAD BYTE
RSF B4
COUNT
RSF B3
0
RSF B2
0
Preliminary Data Sheet
Lucent Technologies Inc.
RSF B1
Lucent Technologies Inc.
0
October 2000
RSF B0
0