HD6432621 Hitachi, HD6432621 Datasheet - Page 478

no-image

HD6432621

Manufacturer Part Number
HD6432621
Description
(HD64F262x Series) 16-Bit Microcomputer
Manufacturer
Hitachi
Datasheet
Bit 2—Transmit End (TEND): Indicates that there is no valid data in TDR when the last bit of
the transmit character is sent, and transmission has been ended.
The TEND flag is read-only and cannot be modified.
Bit 2
TEND
0
1
Bit 1—Multiprocessor Bit (MPB): When reception is performed using multiprocessor format in
asynchronous mode, MPB stores the multiprocessor bit in the receive data.
MPB is a read-only bit, and cannot be modified.
Bit 1
MPB
0
1
Note: * Retains its previous state when the RE bit in SCR is cleared to 0 with multiprocessor
Bit 0—Multiprocessor Bit Transfer (MPBT): When transmission is performed using
multiprocessor format in asynchronous mode, MPBT stores the multiprocessor bit to be added to
the transmit data.
The MPBT bit setting is invalid when multiprocessor format is not used, when not transmitting,
and in clocked synchronous mode.
Bit 0
MPBT
0
1
434
format.
Description
[Clearing conditions]
[Setting conditions]
Description
[Clearing condition]
When data with a 0 multiprocessor bit is received
[Setting condition]
When data with a 1 multiprocessor bit is received
Description
Data with a 0 multiprocessor bit is transmitted
Data with a 1 multiprocessor bit is transmitted
When 0 is written to TDRE after reading TDRE = 1
When the DTC is activated by a TXI interrupt and writes data to TDR
When the TE bit in SCR is 0
When TDRE = 1 at transmission of the last bit of a 1-byte serial transmit character
(Initial value)*
(Initial value)
(Initial value)

Related parts for HD6432621